MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/acr.20527

Медицинская библиотека · Arthritis care & research · 2011

Reproducibility of musculoskeletal ultrasound for determining monosodium urate deposition: concordance between readers.

Howard Rennie G, Pillinger Michael H, Gyftopoulos Soterios, Thiele Ralf G, Swearingen Christopher J, Samuels Jonathan

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Criteria for sonographic diagnosis of monosodium urate (MSU) crystal deposition have been developed, but the interreader reproducibility of this modality is not well established. We therefore assessed agreement using a systematic approach.

METHODS

Fifty male subjects ages 55-85 years were recruited during primary care visits to an urban Veterans Affairs hospital, and were assessed by musculoskeletal ultrasound (US) of the knees and first metatarsophalangeal (MTP) joints to evaluate for the double contour sign and tophi as evidence of MSU crystal deposition. Images were read by 2 blinded rheumatologists trained in musculoskeletal US, and the degree of concordance was determined for individual subjects, total joints, femoral articular cartilage (FAC), and first MTP joints. Subjects were further categorized into 3 diagnostic groups: gout, asymptomatic hyperuricemia (no gout, serum uric acid [UA] ≥6.9 mg/dl), and controls (no gout, serum UA ≤6.8 mg/dl), and reader concordance within these 3 groups was assessed.

RESULTS

We observed almost perfect agreement between readers for 1) individual subjects (yes/no; n = 50, 100% agreement, κ = 1.000), 2) total joints (n = 200, 99% agreement, κ = 0.942), 3) FAC (n = 100, 99% agreement, κ = 0.942), and 4) first MTP joints (n = 100, 99% agreement, κ = 0.942). Furthermore, findings by side (right/left) and diagnostic group (gout, asymptomatic hyperuricemia, control) showed substantial to almost perfect concordance for all measures. MSU deposition was seen most commonly in gout patients, and deposition was also seen in some subjects with asymptomatic hyperuricemia, but in only 1 control.

CONCLUSION

Musculoskeletal US is reliable for detecting MSU deposition in FAC and first MTP joints in gout and asymptomatic hyperuricemia.

Для цитирования: Howard Rennie G, Pillinger Michael H, Gyftopoulos Soterios, Thiele Ralf G, Swearingen Christopher J, Samuels Jonathan. Reproducibility of musculoskeletal ultrasound for determining monosodium urate deposition: concordance between readers.. Arthritis care & research. 2011. DOI: 10.1002/acr.20527.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.