DOI 10.1186/s12891-023-07110-5
Bio-mechanical effects of femoral neck system versus cannulated screws on treating young patients with Pauwels type III femoral neck fractures: a finite element analysis.
Аннотация
INTRODUCTION
As a novel internal fixation for femoral neck fractures, the femoral neck system has some advantages for young Pauwels type III femoral neck fractures without clear biomechanical effects and mechanisms. Thus, the objection of the study is to realize the biomechanical effects and mechanism of FNS cannulated screws on treating young patients with Pauwels type III femoral neck fractures compared to cannulated screws which are commonly used for femoral neck fractures by finite element analysis.
METHODS
Firstly, the model of young Pauwels type III femoral neck fractures, femoral neck system (FNS), and three cannulated screws (CS) arranged in an inverted triangle were established, and the internal fixations were set up to fix young Pauwels type III femoral neck fractures. Under 2100 N load, the finite element was performed, and the deformation, peak von Mises stress (VMS), and contact at fracture segments were recorded to analyze the biomechanical effects and mechanism of FNS and three-CS fixing young Pauwels type III femoral neck fractures.
RESULTS
Compared to three-CS, the deformation of the whole model, internal fixation, and fracture segments after FNS fixation were lower, and the peak VMS of the whole model and the internal fixation after FNS were higher with lower peak VMS of the distal femur and the fracture segments. With a sticking contact status, the contact pressure at fracture segments after FNS fixation was lower than that of three-CS.
CONCLUSIONS
FNS can provide better mechanical effects for young patients with Pauwels type III femoral neck fractures, which may be the mechanical mechanism of the clinical effects of FNS on femoral neck fracture. Although there is high stress on FNS, it is still an effective and safe internal fixation for young patients with Pauwels type III femoral neck fractures.