MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12903-023-03688-3

Медицинская библиотека · BMC oral health · 2024

Influence of occlusal reduction design on the fracture resistance and biomechanical behavior of endocrowns restoring maxillary premolars.

Abbas Mahy Hassouna, Elerian Fatma Abdallah, Elsherbiny Abdallah Ahmed, Elgohary Nesma Mohamed Magdy, Atout Abeer

СтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate the effect of different occlusal reduction design on stress distribution and fracture resistance of different endocrown systems.

MATERIAL AND

METHODS

Sixty-four maxillary human premolars with endodontic treatment, prepared for endocrowns were divided into 2 groups (n = 32) according to the occlusal design: Butt joint preparation (B group) and Anatomical preparation (A group). Each group were subdivided into four groups according to ceramic systems: IPS E max CAD (EM group), monolithic zirconia (ZR group), Nacera Hyprid (NH group) and PEKKTON (PE group). After manufacturing of endocrowns and adhesive bonding the specimens were thermomechanically loaded and subsequently they were tested in a universal testing machine for evaluating the fracture resistance. The specimens failure mode was qualitatively assessed. The stress distribution in each group was assessed using three-dimensional finite element analysis (FEA). 1-way ANOVA and the Post Hoc Tukey HSD test were used to evaluate the data (a = .05).

RESULTS

The fracture resistance values between the groups showed statistically significant variations. The B PE and A PE groups had a higher ratio of fracture resistance values. Regarding failure mode, ceramic endocrowns recorded mainly irreparable failures. FEA showed that anatomical occlusal preparation have reduced the stress concentration under all endocrown systems.

CONCLUSION

Endocrowns could be used to restore endodontically treated maxillary premolars. PEKKTON endocrowns with anatomical preparations revealed most appropriate restoration. The tested new endocrown systems enhanced the biomechanical performance of the tooth.

CLINICAL SIGNIFICANCE: The innovative endocrown systems (PEKK, Nacera Hyprid) can be seen as a promising choice for restoration of severely-destructed endodontic treated premolars, with less stress transmit to the residual tooth structure. Although the traditional endocrown technology might increase the longevity of tooth bonding, it shouldn't be used for clenching cases since the risk of failure is too great overall.

Для цитирования: Abbas Mahy Hassouna, Elerian Fatma Abdallah, Elsherbiny Abdallah Ahmed, Elgohary Nesma Mohamed Magdy, Atout Abeer. Influence of occlusal reduction design on the fracture resistance and biomechanical behavior of endocrowns restoring maxillary premolars.. BMC oral health. 2024. DOI: 10.1186/s12903-023-03688-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.