MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1227/ons.0000000000000872

Медицинская библиотека · Operative neurosurgery (Hagerstown, Md.) · 2023

Rapid Implementation of a 3-Dimensional-Printed Patient-Specific Titanium Sacrum Implant for Severe Neuropathic Spinal Arthropathy and Guide to Compassionate US Regulatory Approval.

Ruiz-Cardozo Miguel A, Trevino Gabriel, Pando Alejandro, Brehm Samuel, Olufawo Michael, Barot Karma, Carey-Ewend Abigail, Yahanda Alexander T, Perdomo-Pantoja Alexander, Jauregui Julio J, Cadieux Magalie, Costa Megan, Coenen Julie, Dorward Ian, Anolik Rachel A, Sacks Justin M, Molina Camilo A

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVE

Rapid design and production of patient-specific 3-dimensional-printed implants (3DPIs) present a novel opportunity to restore the biomechanically demanding integrity of the lumbopelvic junction. We present a unique case of a 61-year-old patient with severe neuropathic spinal arthropathy (Charcot spine) who initially underwent a T4-to-sacrum spinal fusion. Massive bone destruction led to dissociation of his upper body from his pelvis and legs. Reconstruction of the spinopelvic continuity was planned with the aid of a personalized lumbosacral 3DPI.

METHOD: Using high-resolution computed tomography scans, the custom 3DPI was made using additive titanium manufacturing. The unique 3DPI consisted of (1) a sacral platform with iliac screws, (2) modular corpectomy device with rigid connection to the sacral platform, and (3) anterior plate connection with screws for proximal fixation. The procedures to obtain compassionate use Food and Drug Administration approval were followed. The patient underwent debridement of a chronically open wound before undertaking the 3-stage reconstructive procedure. The custom 3DPI and additional instrumentation were inserted as part of a salvage rebuilding procedure.

RESULTS

The chronology of the rapid implementation of the personalized sacral 3DPI from decision, design, manufacturing, Food and Drug Administration approval, and surgical execution lasted 28 days. The prosthesis was positioned in the defect according to the expected anatomic planes and secured using a screw-rod system and a vascularized fibular bone strut graft. The prosthesis provided an ideal repair of the lumbosacral junction and pelvic ring by merging spinal pelvic fixation, posterior pelvic ring fixation, and anterior spinal column fixation.

CONCLUSION

To the best of our knowledge, this is the first case of a multilevel lumbar, sacral, and sacropelvic neuropathic (Charcot) spine reconstruction using a 3DPI sacral prosthesis. As the prevalence of severe spine deformities continues to increase, adoption of 3DPIs is becoming more relevant to offer personalized treatment for complex deformities.

Для цитирования: Ruiz-Cardozo Miguel A, Trevino Gabriel, Pando Alejandro, Brehm Samuel, Olufawo Michael, Barot Karma, Carey-Ewend Abigail, Yahanda Alexander T, Perdomo-Pantoja Alexander, Jauregui Julio J, Cadieux Magalie, Costa Megan, Coenen Julie, Dorward Ian, Anolik Rachel A, Sacks Justin M, Molina Camilo A. Rapid Implementation of a 3-Dimensional-Printed Patient-Specific Titanium Sacrum Implant for Severe Neuropathic Spinal Arthropathy and Guide to Compassionate US Regulatory Approval.. Operative neurosurgery (Hagerstown, Md.). 2023. DOI: 10.1227/ons.0000000000000872.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.