MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/0020-1383(89)90091-0

Медицинская библиотека · Injury · 1989

Hemiarthroplasty of the hip and dislocation.

Paton R W, Hirst P

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

A retrospective study was undertaken on 171 patients who had suffered a subcapital fracture of the neck of the femur between 1982 and 1986. The aim was to compare the dislocation rates in bipolar and monopolar endoprostheses. The basic surgical approaches were utilized: the posterior and direct lateral. Four endoprostheses were employed: Thompson's Moore's (monopolar), Monk's 'hard top', and Charnley-Hastings' (bipolar). There was no significant difference in the dislocation rates between monopolar and bipolar devices. It is concluded that the bipolar devices do not offer any additional protection against dislocation when compared with the traditional monopolar devices.

Для цитирования: Paton R W, Hirst P. Hemiarthroplasty of the hip and dislocation.. Injury. 1989. DOI: 10.1016/0020-1383(89)90091-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.