MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmbbm.2020.103981

Медицинская библиотека · Journal of the mechanical behavior of biomedical materials · 2020

Characterisation of the tensile properties of Demineralised Cortical Bone when used as an anterior cruciate ligament allograft.

Hexter Adam T, Shahbazi Shirin, Thangarajah Tanujan, Kalaskar Deepak, Haddad Fares S, Blunn Gordon

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Graft choice in anterior cruciate ligament (ACL) reconstruction remains controversial and some grafts fail due to inadequate osteointegration. Demineralised cortical bone (DCB) is an osteoinductive collagen-based scaffold. The aim of this study was to measure the tensile properties of DCB from different locations and from different ages, and determine its compatibility with current ACL fixation systems.

METHODS

The tensile properties of DCB manufactured from femur and tibia of young (9 month) and old (2-3 years) sheep was measured to determine the most appropriate graft choice. The ultimate load and stiffness of DCB allograft using two fixation systems, interference screws and sutures tied around screw posts, was measured ex vivo in an ovine ACL reconstruction model. Comparison was made with superficial digital flexor tendon (SDFT) and ovine ACL.

RESULTS

DCB derived from young tibia had the highest ultimate load and stiffness of 67.7 ± 10.6 N and 130.2 ± 64.3 N/mm respectively. No DCB fixation system reached the published peak in vivo force through the ovine ACL of 150 N. SDFT fixation with interference screws (308.2 ± 87.3 N) did reach the in vivo threshold but was significantly weaker than ovine ACL (871.0 ± 64.2 N).

CONCLUSION

The tensile properties of DCB were influenced by the donor age and bone. Owing to inferior tensile properties and incompatibility with suspensory fixation devices, this study indicates DCB is inferior to current tendon grafts options for ACL reconstruction.

Для цитирования: Hexter Adam T, Shahbazi Shirin, Thangarajah Tanujan, Kalaskar Deepak, Haddad Fares S, Blunn Gordon. Characterisation of the tensile properties of Demineralised Cortical Bone when used as an anterior cruciate ligament allograft.. Journal of the mechanical behavior of biomedical materials. 2020. DOI: 10.1016/j.jmbbm.2020.103981.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.