MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.wneu.2023.07.146

Медицинская библиотека · World neurosurgery · 2023

Hounsfield Unit for Evaluating Bone Mineral Density and Strength: Variations in Measurement Methods.

Pu Mengyang, Zhang Bo, Zhu Ying, Zhong Wentao, Shen Yixin, Zhang Peng

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess the consistency and accuracy of various measurements of the Hounsfield unit (HU) in lumbar vertebrae.

METHODS

The study reviewed lumbar spine computed tomography images of 60 postmenopausal women aged >50 years. A total of 240 vertebrae were measured and analyzed for the variations of HU values in different sections and regions. Investigated the relationship between HU values of the lumbar spine under different measurements and dual-energy X-ray absorptiometry results and the ability to identify patients with osteoporosis.

RESULTS

HU values measured in midsagittal (r = 0.763), midcoronal (r = 0.768), and midaxial (r = 0.786) sections exhibited a strong positive correlation with dual-energy X-ray absorptiometry T-scores. HU values measured in midsagittal and midaxial sections of the vertebral body were in good agreement (P > 0.1), but decreased in the midcoronal (P < 0.001). HU values in the middle of the vertebral body were significantly higher than in the near end plate (P < 0.001). HU values varied between L1 and L4 vertebrae, but all had a good ability to identify osteoporosis and did not differ significantly in screening ability (P > 0.05).

CONCLUSIONS

An averaged HU value in axial multilevel is a comprehensive assessment of vertebral bone density. Using the HU value of the lumbar spine can help identify patients with osteoporosis, and the screening ability does not differ significantly across vertebral segments.

Для цитирования: Pu Mengyang, Zhang Bo, Zhu Ying, Zhong Wentao, Shen Yixin, Zhang Peng. Hounsfield Unit for Evaluating Bone Mineral Density and Strength: Variations in Measurement Methods.. World neurosurgery. 2023. DOI: 10.1016/j.wneu.2023.07.146.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.