MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2016.02.020

Медицинская библиотека · Journal of shoulder and elbow surgery · 2016

Total shoulder arthroplasty for glenohumeral arthritis associated with posterior glenoid bone loss: results of an all-polyethylene, posteriorly augmented glenoid component.

Favorito Paul J, Freed Robert J, Passanise Angela M, Brown Maggie Jane

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Posterior glenoid bone loss is commonly encountered in total shoulder arthroplasty (TSA). The purpose of our study is to report the clinical and radiographic findings of patients with a minimum of 2 years' follow-up treated with an all-polyethylene, augmented glenoid component.

METHODS

Twenty-two shoulders with posterior glenoid bone loss were treated by a single surgeon. All underwent primary TSA using a posteriorly augmented, all-polyethylene, stepped glenoid component. Outcome data included visual analog scale, Western Ontario Osteoarthritis of the Shoulder index, and Short Form 36 scores. Radiographic analysis was performed to evaluate bone-cement interface lucency, implant seating, and osseous integration of the central peg.

RESULTS

The mean follow-up period was 36 months. Average preoperative retroversion measured with computed tomography scan was 23.5°. In addition to statistically significant increases in forward flexion and external rotation, the visual analog scale score, Western Ontario Osteoarthritis of the Shoulder score, and Short Form 36 physical component summary score all improved significantly (P < .001). Twelve shoulders had osseous integration between the central-peg flanges, 6 had bone adjacent to the central-peg flanges but without identifiable osseous integration, and 1 showed osteolysis. The mean Lazarus score was 0.5. All glenoids had perfect seating scores. Two patients sustained a total of 3 episodes of prosthetic instability.

CONCLUSIONS

Early results of a posteriorly augmented, all-polyethylene, stepped prosthetic glenoid component to address posterior glenoid loss in TSA are encouraging. Continued evaluation will determine prosthetic longevity and maintained clinical improvement.

Для цитирования: Favorito Paul J, Freed Robert J, Passanise Angela M, Brown Maggie Jane. Total shoulder arthroplasty for glenohumeral arthritis associated with posterior glenoid bone loss: results of an all-polyethylene, posteriorly augmented glenoid component.. Journal of shoulder and elbow surgery. 2016. DOI: 10.1016/j.jse.2016.02.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.