Journal of Parkinson's disease · 2024
Gait Analysis with Wearable Sensors in Isolated REM Sleep Behavior Disorder Associated with Phenoconversion: An Explorative Study.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Cen Shanshan, Zhang Hui, Li Yuan, Gu Zhuqin, Yuan Yuan, Ruan Zheng, Cai Yanning, Chhetri Jagadish K, Liu Shuying, Mao Wei, Chan Piu
Аннотация
BACKGROUND: Gait disturbance is a vital characteristic of motor manifestation in α- synucleinopathies, especially Parkinson's disease. Subtle gait alterations are present in isolated rapid eye movement sleep behavior disorder (iRBD) patients before phenoconversion; it is yet unclear, if gait analysis may predict phenoconversion.
OBJECTIVE: To investigate subtle gait alterations and explore whether gait analysis using wearable sensors is associated with phenoconversion of iRBD to α-synucleinopathies.
METHODS: Thirty-one polysomnography-confirmed iRBD patients and 33 healthy controls (HCs) were enrolled at baseline. All participants walked for a minute while wearing 6 inertial sensors on bilateral wrists, ankles, and the trunk (sternal and lumbar region). Three conditions were tested: (i) normal walking, (ii) fast walking, and (iii) dual-task walking.
RESULTS: Decreased arm range of motion and increased gait variation (stride length, stride time and stride velocity) discriminate converters from HCs at baseline. After an average of 5.40 years of follow-up, 10 patients converted to neurodegenerative diseases (converters). Cox regression analysis showed higher value of stride length asymmetry under normal walking condition to be associated with an early conversion of iRBD to α- synucleinopathies (adjusted HR 4.468, 95% CI 1.088- 18.349, p = 0.038).
CONCLUSIONS: Stride length asymmetry is associated with progression to α- synucleinopathies in patients with iRBD. Gait analysis with wearable sensors may be useful for screening, monitoring, and risk stratification for disease-modifying therapy trials in patients with iRBD.
OBJECTIVE: To investigate subtle gait alterations and explore whether gait analysis using wearable sensors is associated with phenoconversion of iRBD to α-synucleinopathies.
METHODS: Thirty-one polysomnography-confirmed iRBD patients and 33 healthy controls (HCs) were enrolled at baseline. All participants walked for a minute while wearing 6 inertial sensors on bilateral wrists, ankles, and the trunk (sternal and lumbar region). Three conditions were tested: (i) normal walking, (ii) fast walking, and (iii) dual-task walking.
RESULTS: Decreased arm range of motion and increased gait variation (stride length, stride time and stride velocity) discriminate converters from HCs at baseline. After an average of 5.40 years of follow-up, 10 patients converted to neurodegenerative diseases (converters). Cox regression analysis showed higher value of stride length asymmetry under normal walking condition to be associated with an early conversion of iRBD to α- synucleinopathies (adjusted HR 4.468, 95% CI 1.088- 18.349, p = 0.038).
CONCLUSIONS: Stride length asymmetry is associated with progression to α- synucleinopathies in patients with iRBD. Gait analysis with wearable sensors may be useful for screening, monitoring, and risk stratification for disease-modifying therapy trials in patients with iRBD.