MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tbme.2020.3006787

Медицинская библиотека · IEEE transactions on bio-medical engineering · 2021

Knee Compliance Reduces Peak Swing Phase Collision Forces in a Lower-Limb Exoskeleton Leg: A Test Bench Evaluation.

Schrade Stefan O, Menner Marcel, Shirota Camila, Winiger Peter, Stutz Alex, Zeilinger Melanie N, Lambercy Olivier, Gassert Roger

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Powered lower limb exoskeletons are a viable solution for people with a spinal cord injury to regain mobility for their daily activities. However, the commonly employed rigid actuation and pre-programmed trajectories increase the risk of falling in case of collisions with external objects. Compliant actuation may reduce forces during collisions, thus protecting hardware and user. However, experimental data of collisions specific to lower limb exoskeletons are not available. In this work, we investigated how a variable stiffness actuator at the knee joint influences collision forces transmitted to the user via the exoskeleton. In a test bench experiment, we compared three configurations of an exoskeleton leg with a variable stiffness knee actuator in (i) compliant or (ii) stiff configurations, and with (iii) a rigid actuator. The peak torque observed at the pelvis was reduced from 260.2 Nm to 116.2 Nm as stiffness decreased. In addition, the mechanical impulse was reduced by a factor of three. These results indicate that compliance in the knee joint of an exoskeleton can be favorable in case of collision and should be considered when designing powered lower limb exoskeletons. Overall, this could decrease the effort necessary to maintain balance after a collision, and improved collision handling in exoskeletons could result in safer use and benefit their usefulness in daily life.

Для цитирования: Schrade Stefan O, Menner Marcel, Shirota Camila, Winiger Peter, Stutz Alex, Zeilinger Melanie N, Lambercy Olivier, Gassert Roger. Knee Compliance Reduces Peak Swing Phase Collision Forces in a Lower-Limb Exoskeleton Leg: A Test Bench Evaluation.. IEEE transactions on bio-medical engineering. 2021. DOI: 10.1109/tbme.2020.3006787.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.