MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cmi.2025.04.013

Медицинская библиотека · Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases · 2025

Diagnostic accuracy of Truenat MTB Ultima on sputum for pulmonary tuberculosis diagnosis in an HIV-endemic setting.

Abdulgader Shima M, Chiwaya Arthur M, Nwamba Welile V, Reeve Byron W P, Palmer Zaida, Mishra Hridesh, Mbu Desiree, Lushozi Nondumiso, Nkwanyana Zola, Ruhwald Morten, Penn-Nicholson Adam, Warren Robin, Theron Grant

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Assess Truenat MTB Ultima (Ultima) diagnostic accuracy, alongside standard-of-care Truenat MTB Plus (MTB Plus) and Xpert MTB/RIF Ultra (Ultra) tests, for pulmonary tuberculosis (TB) diagnosis in a high-burden setting. We secondarily evaluated Truenat MTB-RIF Dx (MTB-RIF Dx) on Ultima- or MTB Plus-positive samples for rifampicin susceptibility diagnosis.

METHODS

Adults (≥18 years; n = 498) with presumptive TB self-presenting to primary care clinics in Cape Town, South Africa (19/02/2016-22/02/2023) provided sputa. The microbiological reference standard was a single culture for TB and MTBDRplus on an isolate for rifampicin susceptibility.

RESULTS

In total, 54% (n = 269) of the participants had HIV, and 42% (n = 210) had previous TB. The proportion of Ultima and MTB Plus unsuccessful results was 14% (95% CI 11, 16) and 20% (17, 23), respectively, with at least half resolving upon retesting the same eluate. In a three-way analysis, Ultima, MTB Plus, and Ultra had TB sensitivities of 90% (85, 93), 84% (78, 88), and 92% (87, 95) and specificities of 85% (80, 88), 95% (92, 97), and 95% (92, 97). Ultima specificity did not improve with Ultra in the reference standard. MTB-RIF Dx had high unsuccessful result rates that varied if done on the day of DNA extraction or on Ultima- [18% (10, 26) vs. 44% (35, 51) if after day of extraction] or MTB Plus-positive eluates [9% (3, 16) vs. 27% (18, 35)]. Same day rifampicin susceptibility testing was often unsuccessful in samples with the "very low" semiquantitation category reported by Ultima [75% (65, 86)] or MTB Plus [73% (58, 89)] but had 100% (40, 100) sensitivity and 99% (96, 100) specificity (on both MTB Plus- or Ultima-positive DNA). Reagent lot variation in unsuccessful and false positive results was observed.

DISCUSSION: Ultima met the minimum sensitivity recommended by the WHO for TB detection, but specificity, reagent lot variation, and unsuccessful results were suboptimal.

Для цитирования: Abdulgader Shima M, Chiwaya Arthur M, Nwamba Welile V, Reeve Byron W P, Palmer Zaida, Mishra Hridesh, Mbu Desiree, Lushozi Nondumiso, Nkwanyana Zola, Ruhwald Morten, Penn-Nicholson Adam, Warren Robin, Theron Grant. Diagnostic accuracy of Truenat MTB Ultima on sputum for pulmonary tuberculosis diagnosis in an HIV-endemic setting.. Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases. 2025. DOI: 10.1016/j.cmi.2025.04.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.