MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ehf2.15072

Медицинская библиотека · ESC heart failure · 2024

Factors associated with stellate ganglion block success in recurrent ventricular arrhythmias.

Chouairi Fouad, Fudim Marat, Benak Ales, Piccini Jonathan P, Toman Jakub, Kautzner Josef, Ganesh Arun, Sramko Marek

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

AIMS: One treatment option for refractory ventricular arrythmias is stellate ganglion block (SGB). We examined differences in SGB success by patient and arrhythmia characteristics and predictors of successful SGB.

METHODS AND

RESULTS

This was a multicenter analysis of patients treated for refractory ventricular arrythmias in the Czech Republic and the United States. The primary outcome was absence of ventricular arrythmias at 24 h post SGB. SGB effectiveness was examined according to aetiology of cardiomyopathy, arrhythmia type, laterality of SGB, presence of inotropes, and presence of mechanical circulatory support. Binary logistic regression was used to examine variables associated with the primary outcome. In total there were 117 patients with refractory ventricular arrythmias treated with SGB. Overall, the mean age was 63.5 ± 11.0 years, majority of patients were male (94.0%), White (87.2%), and had an implantable cardioverter defibrillator in situ (70.1%). There were no differences in efficacy of SGB based on aetiology of cardiomyopathy (P = 0.623), arrhythmia type (0.852), laterality of block (P = 0.131), and presence of inotropes (P = 0.083). Multivariable analysis demonstrated that increased age was associated with decreased odds of SGB success (odds ratio: 0.96, confidence interval: 0.92-0.99, P = 0.039) whereas increased left ventricular ejection fraction trended towards increased odds of SGB success (odds ratio: 1.05, confidence interval: 0.995-1.11, P = 0.077).

CONCLUSIONS

In this multicentre experience, SGB was similarly effective despite the aetiology of cardiomyopathy, type of arrhythmia, laterality, and inotropic or mechanical support. SGB was less effective for the suppression of ventricular arrythmias at 24 h for the elderly.

Для цитирования: Chouairi Fouad, Fudim Marat, Benak Ales, Piccini Jonathan P, Toman Jakub, Kautzner Josef, Ganesh Arun, Sramko Marek. Factors associated with stellate ganglion block success in recurrent ventricular arrhythmias.. ESC heart failure. 2024. DOI: 10.1002/ehf2.15072.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.