MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21873/invivo.13420

Медицинская библиотека · In vivo (Athens, Greece) · 2024

Development, Validation and Characterization of a Novel Portable Closed Fracture Device.

Zhang Long, Shi Xueqing, Chen Xiaohui, Rui Gang, Li N A, Akimoto Yoshie, Zhang Mingxia, Chen Y U, Xu Ren

СтатьяПеревод в очереди

Аннотация

BACKGROUND/AIM: As one of the common clinical diseases, fractures have many causes, mechanisms, healing and influencing factors; especially fracture healing is a long-term and complex process. Animal fracture models can simulate the various states of human fractures, and on this basis, the prevention, mechanism, and treatment of fractures can be studied to further guide clinical practice.

MATERIALS AND

METHODS

Here, we developed a novel and portable device to create a closed fracture model in mice. We then compared this novel closed fracture model with the traditional open model in multiple dimensions to evaluate the modelling process of establishment and healing. The two models were evaluated by imaging, immunostaining, and behavioral tests, which fully demonstrated the stability, universality and operability of the modified fracture model in mice.

RESULTS

Surgical quality assessment revealed that the closed fracture model had a shorter operation time and smaller wound than the open model. X-ray and micro-CT results showed no differences between the two models in the evaluation of radiographic and morphological changes during fracture healing. Histological examination revealed the process of the typical intrachondral osteogenic pathway after fracture. Moreover, animal gait analysis indicated reduced postoperative pain in the closed group compared to the open group.

CONCLUSION

This study provides a constructive strategy for a closed fracture model in mice and demonstrates the effectiveness and feasibility of the closed fracture model in studying the typical intrachondral osteogenic pathway of fractures from multiple dimensions.

Для цитирования: Zhang Long, Shi Xueqing, Chen Xiaohui, Rui Gang, Li N A, Akimoto Yoshie, Zhang Mingxia, Chen Y U, Xu Ren. Development, Validation and Characterization of a Novel Portable Closed Fracture Device.. In vivo (Athens, Greece). 2024. DOI: 10.21873/invivo.13420.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.