Reverse traction with Kirschner wires and bilateral external fixation device combined with minimally invasive plate oseoynthesis technique for tibial plateau fractures of type Schatzker V and VI.

Zhao Wei-Qiang, Li Xu-Song, Hua Jiang, Huang Jie-Feng

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Complex bicondylar tibial plateau fracture (TPF) has always been a tricky problem for surgeons. We created a novel external device used intraoperatively consisting of Kirschner wires, and combined with minimally invasive plate oseoynthesis (MIPO) technique to treat complex bicondylar TPFs, and the clinical effect and feasibility were further evaluated.

METHODS

From March 2016 to February 2021, 49 cases (29 males and 20 females) were identified as bicondylar TPF, the mean age 47.2 (27-69). All patients adopted the device and MIPO technique. A series of score, complications, and radiographs in the follow-up period, from three months, six months, one year, and two years and the last follow-up, were recorded, from visual analogue score (VAS), hospital for special surgery (HSS), and Short-Form 36 (SF-36), containing physical (PCS) and mental (MCS), and Rasmussen score.

RESULTS

Forty-seven patients showed good functional recovery. No patients were lost, mean follow-up time was 28.17 ± 2.81 (24.2-35.4) months. Operation time was 89.80 ± 13.46 (58-110) min. At the last follow-up, VAS was 1.3 ± 0.92 (0-4), HHS was 93.10 ± 2.63 (89-99), PCS was 49.20 ± 7.40 (38-65), and MCS was 50.08 ± 4.77 (43-62). Complications were as follows: cutaneous necrosis (3, 6%), asymptomatic arthritis (3, 6%), symptomatic arthritis (1, 2%), and deep venous thrombosis (1, 2%). Mean fracture healing time was 11.82 ± 1.5 (10-15.4) weeks. All patients got recovery without extra surgery and removed the implants at 12.85 ± 0.76 (11.2-15.4) months.

CONCLUSION

Temporary traction device of bilateral external fixator combined with MIPO technique was simple and convenient, with a smaller soft-tissue damage, an easier operational approach, and its worth being promoted.

Для цитирования: Zhao Wei-Qiang, Li Xu-Song, Hua Jiang, Huang Jie-Feng. Reverse traction with Kirschner wires and bilateral external fixation device combined with minimally invasive plate oseoynthesis technique for tibial plateau fractures of type Schatzker V and VI.. International orthopaedics. 2023. DOI: 10.1007/s00264-023-05877-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.