MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-020-06952-0

Медицинская библиотека · European radiology · 2020

The association between patellar tendon stiffness measured with shear-wave elastography and patellar tendinopathy-a case-control study.

Breda Stephan J, van der Vlist Arco, de Vos Robert-Jan, Krestin Gabriel P, Oei Edwin H G

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

(1) To determine the association between patellar tendon stiffness and the presence of patellar tendinopathy (PT). (2) To evaluate the reliability of shear-wave elastography (SWE).

METHODS

Participants were consecutively enrolled between January 2017 and June 2019. PT was diagnosed clinically and confirmed by either grayscale US or power Doppler US, or both. Controls had no history of anterior knee pain and no clinical signs of PT. Patellar tendon stiffness (kilopascal, kPa) was assessed using SWE. Logistic regression was used to estimate adjusted odds ratios (ORs) and 95% confidence intervals (CIs). Reliability analyses included coefficients-of-variation (CV), coefficients-of-repeatability (CR), intraclass correlation coefficient (ICC) for intraobserver and interobserver reliability, and Bland-Altman analysis.

RESULTS

In total, 76 participants with PT (58 men, mean age 24.4 ± 3.8 years) and 35 asymptomatic controls (16 men, mean age 21.5 ± 3.8 years) were included. Univariate analyses (OR 1.094, 95% CI 1.061-1.128, p < .001) and adjusted multivariate analyses (OR 1.294, 95% CI 1.044-1.605, p = .018) showed that athletes with PT had significantly increased patellar tendon stiffness. ICC for intraobserver reliability was 0.95 (95% CI 0.92-0.97), CR (CV) 12 kPa (10%) and 0.79 (95% CI 0.65-0.88), CR (CV) 18 kPa (21%) for interobserver reliability. Mean differences from Bland-Altman analysis were 5.6 kPa (95% CI 3.1-8.1, p < .001) for intraobserver reliability and 4.6 kPa (95% CI 1.9-7.2, p < .001) for interobserver reliability.

CONCLUSIONS

PT is associated with significantly higher patellar tendon stiffness. SWE measurements demonstrate excellent intraobserver reliability and good interobserver reliability. Therefore, SWE is a promising tool to implement in longitudinal studies and future studies should evaluate its prognostic value and utility as a monitoring tool in athletes with PT.

KEY POINTS: • Patellar tendon stiffness measured with shear-wave elastography (SWE) is higher in athletes with patellar tendinopathy than in healthy controls, also after adjusting for potential confounders. • Excellent intraobserver reliability and good interobserver reliability were found for the quantitative assessment of patellar tendon stiffness using SWE.

Для цитирования: Breda Stephan J, van der Vlist Arco, de Vos Robert-Jan, Krestin Gabriel P, Oei Edwin H G. The association between patellar tendon stiffness measured with shear-wave elastography and patellar tendinopathy-a case-control study.. European radiology. 2020. DOI: 10.1007/s00330-020-06952-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.