MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/19322968241252819

Медицинская библиотека · Journal of diabetes science and technology · 2024

Using Artificial Intelligence to Improve the Accuracy of a Wrist-Worn, Noninvasive Glucose Monitor: A Pilot Study.

Qureshi Muhammad Rafaqat Ali, Bain Stephen Charles, Luzio Stephen, Handy Consuelo, Fowles Daniel J, Love Bradley, Wareham Kathie, Barlow Lucy, Dunseath Gareth J, Crane Joel, Masso Isamar Carrillo, Ryan Julia A M, Chaudhry Mohamed Sabih

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Self-monitoring of glucose is important to the successful management of diabetes; however, existing monitoring methods require a degree of invasive measurement which can be unpleasant for users. This study investigates the accuracy of a noninvasive glucose monitoring system that analyses spectral variations in microwave signals.

METHODS

An open-label, pilot design study was conducted with four cohorts (N = 5/cohort). In each session, a dial-resonating sensor (DRS) attached to the wrist automatically collected data every 60 seconds, with a novel artificial intelligence (AI) model converting signal resonance output to a glucose prediction. Plasma glucose was measured in venous blood samples every 5 minutes for Cohorts 1 to 3 and every 10 minutes for Cohort 4. Accuracy was evaluated by calculating the mean absolute relative difference (MARD) between the DRS and plasma glucose values.

RESULTS

Accurate plasma glucose predictions were obtained across all four cohorts using a random sampling procedure applied to the full four-cohort data set, with an average MARD of 10.3%. A statistical analysis demonstrates the quality of these predictions, with a surveillance error grid (SEG) plot indicating no data pairs falling into the high-risk zones.

CONCLUSIONS

These findings show that MARD values approaching accuracies comparable to current commercial alternatives can be obtained from a multiparticipant pilot study with the application of AI. Microwave biosensors and AI models show promise for improving the accuracy and convenience of glucose monitoring systems for people with diabetes.

Для цитирования: Qureshi Muhammad Rafaqat Ali, Bain Stephen Charles, Luzio Stephen, Handy Consuelo, Fowles Daniel J, Love Bradley, Wareham Kathie, Barlow Lucy, Dunseath Gareth J, Crane Joel, Masso Isamar Carrillo, Ryan Julia A M, Chaudhry Mohamed Sabih. Using Artificial Intelligence to Improve the Accuracy of a Wrist-Worn, Noninvasive Glucose Monitor: A Pilot Study.. Journal of diabetes science and technology. 2024. DOI: 10.1177/19322968241252819.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.