Clinical biomechanics (Bristol, Avon) · 2020

Assessment of fixation for anterior cruciate ligament reconstruction using oversized suspensory devices on full-length femoral tunnels.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Prado-Nóvoa María, Pérez-Blanca Ana, Espejo-Reina Alejandro, Lombardo-Torre Maximiano, Ezquerro-Juanco Francisco, Espejo-Baena Alejandro

Аннотация

BACKGROUND: In ACL repair, full-length single-diameter tunnels facilitate anatomic femoral fixation with suspensory devices, especially with outside-in techniques, and are required after accidental cortical perforation. With tunnel diameters over 6 mm, fixation resistance using regular suspensory devices may not suffice. Oversized cortical footprint devices could be a solution to guarantee fixation performance in larger tunnel diameters. This study aims to assess the biomechanical properties of ACL femoral fixation provided by two enlarged suspensory devices of similar characteristics, a fixed loop (G-Lok™ with G-Lok-XL™) and an adjustable loop (ProCinch™ with G-Lok-XL™), resting on a full-length 9 mm diameter tunnel compared to the widely accepted regular fixed-loop device (G-Lok™) on a socket tunnel.

METHODS: Twenty-seven fresh frozen porcine femurs and flexor digitorum profundus tendons were randomly assigned to a study group depending on the fixation method used (N = 9). Graft-femur constructs were subjected to a traction cyclic test (5000 cycles, [50-250]N load, 1 Hz) followed by a load-to-failure test (v = 1 mm/s). Residual displacement during the cyclic test and stiffness, displacements at physiological loads, ultimate load and corresponding displacement during the load-to-failure test were determined.

FINDINGS: No significant differences could be established for any parameter measured in the comparison between the control with the socket tunnel and the oversized fixations with full-length tunnels.

INTERPRETATION: ACL femoral fixation achieved in full-length single diameter tunnels by using an enlarged suspension device, both with a fixed or an adjustable loop, provide similar biomechanical properties to the gold-standard fixed-loop device in a socket tunnel. Therefore, its clinical use may be safe.

Предметные рубрики MeSH