DOI 10.1007/s00402-021-03826-y
Management, outcome, and novel classification system of periprosthetic fractures in patients with transcutaneous osseointegrated prosthetic systems (TOPS)-a retrospective cohort analysis.
Аннотация
INTRODUCTION
Transcutaneous osseointegrated prosthetic systems (TOPS) are anchored prosthetic systems for major limb loss. Sometimes TOPS patients suffer from periprosthetic fractures. The aim of this study was to analyze the management and outcomes of periprosthetic fractures in patients with TOPS and to introduce a novel classification system for this entity.
MATERIAL/
METHODS
Since 2010, 140 patients were treated with TOPS after transfemoral amputation in two centers in Germany. Fifteen patients sustained periprosthetic fractures, with five intra- and ten postoperative fractures. The outcome was analyzed by Prosthesis Mobility Questionnaire (PMQ), K-level and prosthesis wear time per day. A subgroup analysis for the body mass index (BMI) was performed.
RESULTS
All postoperative fractures were treated with implant-retaining osteosynthesis. Fourteen fractures healed without complications after a mean of 3 months. One postoperative fracture developed a clinically asymptomatic firm non-union. No Endo-Fixstem had to be removed. For the fracture and control group, a significant increase of the PMQ (p < 0.001) and K-level (p < 0.001) was observed after TOPS treatment compared to the preoperative baseline. Furthermore, the subgroup analysis showed a significant increase of the PMQ and K-level for both normal weight (p = 0.002) and overweight patients (p < 0.001). Of interest, overweight patients even showed a significantly higher increase in scores compared to normal weight patients, regardless of periprosthetic fracture.
CONCLUSION
Periprosthetic fractures do not necessarily worsen outcomes of TOPS treatment. Proper classification and standardized appropriate treatment strategies according to fracture morphology are paramount for reliably good outcomes. We recommend to not remove or exchange the implant (Endo-Fixstem) even if it is assembly. Higher BMI did not have an impact onto rehabilitation success after TOPS to major limb loss of the lower extremity.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.