MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00003086-200111000-00025

Медицинская библиотека · Clinical orthopaedics and related research · 2001

Posterior-stabilized and cruciate-retaining total knee replacement: a randomized study.

Clark C R, Rorabeck C H, MacDonald S, MacDonald D, Swafford J, Cleland D

Клиническое исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод в очереди

Аннотация

A randomized controlled study was done to compare the clinical, radiographic, and quality of life outcomes between posterior-stabilized and cruciate-retaining primary total knee implants. One hundred forty-three patients were enrolled in the study. Patients ranged in age from 57 to 89 years, had a primary diagnosis of osteoarthritis, and an intact functioning posterior cruciate ligament. Patients were excluded if they had a flexion contracture greater than 15 degrees, a varus deformity greater than 20 degrees, or a valgus deformity greater than 15 degrees. Patients were randomized to one of two study groups, posterior-stabilized AMK total knee implants (76 patients) or cruciate-retaining AMK total knee implants (67 patients). One hundred eight patients have had a minimum 2-year followup including 57 patients in the posterior-stabilized group and 51 patients in the cruciate-retaining group. Seventy-three patients have had a minimum 3-year followup including 37 patients in the posterior stabilized group and 36 patients in the cruciate-retaining group. The overall total Knee Society clinical rating score at 2 years averaged 157.1 points in the posterior-stabilized group and 156.5 points in the cruciate-retaining group. At 3 years, the scores averaged 156.8 points in the posterior-stabilized group and 163.5 points in the cruciate-retaining group. The range of motion component of the Knee Society score averaged 113.6 degrees for the posterior-stabilized group and 108.5 degrees for the cruciate-retaining group at 2 years, and 108.3 degrees in the cruciate-retaining group and 108.5 degrees in the posterior-stabilized group. Based on the various parameters analyzed, there were no notable differences between the groups with a posterior-stabilized and a cruciate-retaining total knee implant at 2 years. This trend seemed to be the same at 3 years.

Для цитирования: Clark C R, Rorabeck C H, MacDonald S, MacDonald D, Swafford J, Cleland D. Posterior-stabilized and cruciate-retaining total knee replacement: a randomized study.. Clinical orthopaedics and related research. 2001. DOI: 10.1097/00003086-200111000-00025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.