DOI 10.1016/j.injury.2021.02.040
Do Poller screws effect union in tibial shaft fractures treated with intramedullary nailing?
Аннотация
INTRODUCTION
Tibial shaft fractures are a commonly encountered challenge presented to orthopaedic trauma surgeons. Intramedullary nailing (IMN) is often the treatment of choice and whilst effective, complications of delayed and/or non-union can cause significant morbidity and necessitate additional operative procedures. The use of Poller screws during IMN are a recognised way of aiding fracture reduction, however the clinical benefits of this are debated. This study evaluated the outcome of tibial shaft fractures treated with IMN with or without the addition of Poller screws.
METHODS
Retrospective cohort study of all patients undergoing IMN following tibial shaft fractures over a 5-year period. 154 operated tibial shaft fractures were identified, with patients divided into 3 groups - Group 1: IM nailing alone, Group 2: IMN + 1 conventional Poller screw, or Group 3: IMN + 2 Poller screws placed Epicentrically across the fracture site. Data collected included demographics, length of stay, fracture type, position and AO classification grade, operative time, and operating surgeons' grade. Primary outcome measure was the incidence of delayed and/or non-union. Secondary outcomes were differences in rates of infection and additional orthopaedic procedures between the 3 groups.
RESULTS
Overall 139/154 fractures (90.3%) achieved a timely union. There was a statistically significant difference (p = 0.05) in fracture union between the 3 groups, with 75/88 fractures healing in group 1 (IMN alone) compared to 44/46 in Group 2 (IMN + 1 Poller screw) and 20/20 in group 3 (IMN + 2 Poller screws). There was no statistical difference in the incidence of superficial infection, (p = 0.95) additional procedures (p = 0.23) or deep infection (p = 0.65) between the 3 groups.
CONCLUSION
The addition of Poller screws appear to be a safe and effective adjunct in the treatment of tibial shaft fractures via IMN. Further prospective randomised trials are needed to fully elucidate both the role and potential benefits of Poller screw augmentation in acute lower limb fracture management.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.