MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.heliyon.2024.e32544

Медицинская библиотека · Heliyon · 2024

Quantifying lumbar mobility using a single tri-axial accelerometer.

Evans David W, Wong Ian T Y, Leung Hoi Kam, Yang Hanyun, Liew Bernard X W

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Lumbar mobility is regarded as important for assessing and managing low back pain (LBP). Inertial Measurement Units (IMUs) are currently the most feasible technology for quantifying lumbar mobility in clinical and research settings. However, their gyroscopes are susceptible to drift errors, limiting their use for long-term remote monitoring.

RESEARCH QUESTION: Can a single tri-axial accelerometer provide an accurate and feasible alternative to a multi-sensor IMU for quantifying lumbar flexion mobility and velocity?

METHODS

In this cross-sectional study, 18 healthy adults performed nine repetitions of full spinal flexion movements. Lumbar flexion mobility and velocity were quantified using a multi-sensor IMU and just the tri-axial accelerometer within the IMU. Correlations between the two methods were assessed for each percentile of the lumbar flexion movement cycle, and differences in measurements were modelled using a Generalised Additive Model (GAM).

RESULTS

Very high correlations (r > 0.90) in flexion angles and velocities were found between the two methods for most of the movement cycle. However, the accelerometer overestimated lumbar flexion angle at the start (-4.7° [95 % CI -7.6° to -1.8°]) and end (-4.8° [95 % CI -7.7° to -1.9°]) of movement cycles, but underestimated angles (maximal difference of 4.3° [95 % CI 1.4° to 7.2°]) between 7 % and 92 % of the movement cycle. For flexion velocity, the accelerometer underestimated at the start (16.6°/s [95%CI 16.0 to 17.2°/s]) and overestimated (-12.3°/s [95%CI -12.9 to -11.7°/s]) at the end of the movement, compared to the IMU.

SIGNIFICANCE: Despite the observed differences, the study suggests that a single tri-axial accelerometer could be a feasible tool for continuous remote monitoring of lumbar mobility and velocity. This finding has potential implications for the management of LBP, enabling more accessible and cost-effective monitoring of lumbar mobility in both clinical and research settings.

Для цитирования: Evans David W, Wong Ian T Y, Leung Hoi Kam, Yang Hanyun, Liew Bernard X W. Quantifying lumbar mobility using a single tri-axial accelerometer.. Heliyon. 2024. DOI: 10.1016/j.heliyon.2024.e32544.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.