MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.knee.2015.10.008

Медицинская библиотека · The Knee · 2016

Long-term results of total knee arthroplasty in young and active patients with posterior stabilized design.

Meftah Morteza, White Peter B, Ranawat Amar S, Ranawat Chitranjan S

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The aim of this study was to evaluate long-term quality and performance of cemented posterior-stabilized (PS) total knee arthroplasty (TKA) in young and active patients with gap balancing technique.

METHODS

Between January 2000 and October 2001, 55 TKAs (21 rotating platform [RP] and 34 fixed bearing [FB]) in 41 patients, 60 years and younger, with University of California Los Angeles (UCLA) activity score of five and above were included in this study and prospectively followed. Clinical assessments included Western Ontario and McMaster Universities (WOMAC), Knee Society, UCLA activity score, and Patient Administered Questionnaire (PAQ). Radiographic measurements included component positioning, patellar tilt and thickness, radiolucency, loosening or osteolysis.

RESULTS

At a mean follow-up of 12.3±0.5 years (11 to 13), there was no instability, malalignment, or patellofemoral maltracking. Sixty eight percent of patients were still participating in regular recreational activities at the final follow-up. The mean satisfaction score was 9.1±1.9 and 8.5±2.1 in RP-PS and FB-PS groups, respectively. There was no malalignment or osteolysis, no revision for osteolysis or loosening. One patient in the FB-PS group underwent open reduction and internal fixation for a peri-prosthetic fracture. Overall Kaplan-Meier survivorship was 98%.

CONCLUSION

The PS TKA in young and active patients can provide long-term durability and high quality of function.

LEVEL OF EVIDENCE: III.

Для цитирования: Meftah Morteza, White Peter B, Ranawat Amar S, Ranawat Chitranjan S. Long-term results of total knee arthroplasty in young and active patients with posterior stabilized design.. The Knee. 2016. DOI: 10.1016/j.knee.2015.10.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.