MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1120700020985067

Медицинская библиотека · Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2021

Integrated dual lag screws versus single lag screw cephalomedullary nail constructs: a meta-analysis and systematic review.

Onggo James R, Nambiar Mithun, Onggo Jason D, Ambikaipalan Anuruban, Singh Parminder J, Babazadeh Sina

СтатьяМетаанализСистематический обзорПеревод в очереди

Аннотация

BACKGROUND/AIM: This study aims to determine the safety and efficacy of integrated dual lag screw (IDL) cephalomedullary nails (CMN) when compared with single lag screw (SL) constructs, in the internal fixation of intertrochanteric femoral fractures.

METHODS

The Smith & Nephew InterTan IDL was compared with SL CMN group consisting of the Stryker Gamma-3 (G3) and Synthes Proximal Femoral Nail Antirotation (PFNA) CMN. A multi-database search was performed according to PRISMA guidelines. Data from studies assessing the clinical and radiological outcomes, complications and perioperative parameters of InterTan versus G3 or PFNA CMN in patients with intertrochanteric femoral fractures were extracted and analysed.

RESULTS

15 studies were included in this meta-analysis, consisting of 2643 patients. InterTan was associated with lower complication rates in terms of all-cause revisions (OR 0.34; 95% CI, 0.22-0.51; p < 0.001), cut-outs (OR 0.30; 95% CI, 0.17-0.51; p < 0.001), medial or lateral screw migration (OR 0.19; 95% CI, 0.06-0.65; p = 0.008) as well as persistent hip and thigh pain (OR 0.65; 95% CI, 0.47-0.90; p = 0.008). In terms of perioperative parameters, InterTan is associated with longer operative times (MD 5.57 minutes; 95% CI, 0.37-10.78 minutes, p = 0.04) and fluoroscopy times (MD 38.89 seconds, 95% CI, 15.88-61.91 seconds; p < 0.001). There was no statistically significant difference in terms of clinical Harris Hip Score and radiological outcomes, non-union, haematoma, femoral fractures, varus collapse, length of stay and mean intraoperative blood loss between the 2 groups.

CONCLUSIONS

Integrated dual lag screw cephalomedullary nails are associated with fewer revisions and complications. However, there is insufficient data to suggest that either nail construct is associated with better functional outcomes.

Для цитирования: Onggo James R, Nambiar Mithun, Onggo Jason D, Ambikaipalan Anuruban, Singh Parminder J, Babazadeh Sina. Integrated dual lag screws versus single lag screw cephalomedullary nail constructs: a meta-analysis and systematic review.. Hip international : the journal of clinical and experimental research on hip pathology and therapy. 2021. DOI: 10.1177/1120700020985067.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.