MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3233/thc-235007

Медицинская библиотека · Technology and health care : official journal of the European Society for Engineering and Medicine · 2023

Experimental and theoretical investigation of aortic wall tissue in tensile tests.

Petuchova Aleksandra, Maknickas Algirdas, Kostenko Ernest, Stonkus Rimantas

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Understanding the mechanical properties of aortic tissue is essential for developing numerical computation tools and assessing the risk of aortic aneurysm fractures. Tensile tests using aortic wall specimens allow for the determination of stress and strain depending on the location and direction of the sample.

OBJECTIVE

The aim of this study was to perform a mechanical tensile test using canine aorta samples and create a numerical model of aortic tissue tension from the processed data.

METHODS

Dogbone-shaped samples were dissected from canine aortic segments. The initial measurements were made at zero tension and the tensile tests were conducted at 10 mm/min until rupture. Force and stretch data were used to obtain engineering and true stress-strain curves. The true stress-strain curves were taken until the maximum strength was obtained, after which they were smoothed and fitted using a logistic function with three coefficients. These curves were then used as material mechanical properties for a numerical model of the aortic tissue tension. A simplified rectangle form was used to mimic the middle of the dogbone-shaped portion of the tissue specimen. Experimental displacement data were collected for the boundary conditions of the finite element 3D model.

RESULTS

The experimental data processing revealed that the logistic function described the nonlinear behaviour of the aorta soft tissue with an accuracy of 95% from the start of the tension to the media layer rupture. By applying numerical simulations, we obtained a correspondence of the load curve with an RMSE = 0.069 for the theoretical and experimental external tension data.

CONCLUSION

The numerical investigation confirmed that the non-linear soft tissue was validated by applying a logistic function approach to the mechanical properties of the aortic wall.

Для цитирования: Petuchova Aleksandra, Maknickas Algirdas, Kostenko Ernest, Stonkus Rimantas. Experimental and theoretical investigation of aortic wall tissue in tensile tests.. Technology and health care : official journal of the European Society for Engineering and Medicine. 2023. DOI: 10.3233/thc-235007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.