MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Chinese medical journal · 2009

Management of intra-articular fracture of the fingers via mini external fixator combined with limited internal fixation.

Li Wen-jun, Tian Wen, Tian Guang-lei, Chen Shan-lin, Zhang Chang-qing, Xue Yun-hao, Li Zhong-zhe, Zhu Yin

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Intra-articular fractures of the fingers are common problems to emergency physicians and hand surgeons. Inappropriate management of these injuries may result in chronic pain, stiffness, deformity, or post traumatic arthritis. Ideal treatment necessitates the restoration of a stable and congruent joint that will allow early mobilization. The purpose of this study was to investigate the results of intra-articular fracture of the fingers by mini external fixator combined with limited internal fixation.

METHODS

From May 2005 to May 2007, a total of 26 patients with intra-articular fracture of the fingers were treated by mini external fixator combined with limited internal fixation. Of the 26 cases, 11 involved in metacarpophalangeal joint, and 15 interphalangeal joint in proximal interphalangeal. Kirschner wire, mini wire and absorbable suture were used for limited internal fixation. All patients were followed up and patients were accomplished with total active motion (TAM) of fingers.

RESULTS

All patients were reviewed by an independent observer. The mean follow up was 13 months (range 9 to 24 months). Subjective, objective and radiographic results were evaluated. X-ray films revealed fracture union and the average radiographic union time was 7 weeks with a range of 5 - 12 weeks and the phalange shortening or rotation in 2 cases, joint incongruity (less than 1 mm) and joint space narrowing in 3 cases respectively. Phalangeal shortening or rotation was observed in 2 cases and joint incongruity or joint space narrowing was observed in 3 cases. An artificial implant was performed on one case for traumatic arthritis 1.5 years after surgery. Based on TAM the overall good-excellent rate of joint motion function was 80.8%.

CONCLUSION

Mini external fixator combined with limited internal fixation is a reliable and effective method for treatment of intra-articular fracture of the fingers.

Для цитирования: Li Wen-jun, Tian Wen, Tian Guang-lei, Chen Shan-lin, Zhang Chang-qing, Xue Yun-hao, Li Zhong-zhe, Zhu Yin. Management of intra-articular fracture of the fingers via mini external fixator combined with limited internal fixation.. Chinese medical journal. 2009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.