MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-024-10744-1

Медицинская библиотека · European radiology · 2024

Artificial intelligence for automated detection and measurements of carpal instability signs on conventional radiographs.

Hendrix Nils, Hendrix Ward, Maresch Bas, van Amersfoort Job, Oosterveld-Bonsma Tineke, Kolderman Stephanie, Vestering Myrthe, Zielinski Stephanie, Rutten Karlijn, Dammeier Jan, Ong Lee-Ling Sharon, van Ginneken Bram, Rutten Matthieu

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To develop and validate an artificial intelligence (AI) system for measuring and detecting signs of carpal instability on conventional radiographs.

MATERIALS AND

METHODS

Two case-control datasets of hand and wrist radiographs were retrospectively acquired at three hospitals (hospitals A, B, and C). Dataset 1 (2178 radiographs from 1993 patients, hospitals A and B, 2018-2019) was used for developing an AI system for measuring scapholunate (SL) joint distances, SL and capitolunate (CL) angles, and carpal arc interruptions. Dataset 2 (481 radiographs from 217 patients, hospital C, 2017-2021) was used for testing, and with a subsample (174 radiographs from 87 patients), an observer study was conducted to compare its performance to five clinicians. Evaluation metrics included mean absolute error (MAE), sensitivity, and specificity.

RESULTS

Dataset 2 included 258 SL distances, 189 SL angles, 191 CL angles, and 217 carpal arc labels obtained from 217 patients (mean age, 51 years ± 23 [standard deviation]; 133 women). The MAE in measuring SL distances, SL angles, and CL angles was respectively 0.65 mm (95%CI: 0.59, 0.72), 7.9 degrees (95%CI: 7.0, 8.9), and 5.9 degrees (95%CI: 5.2, 6.6). The sensitivity and specificity for detecting arc interruptions were 83% (95%CI: 74, 91) and 64% (95%CI: 56, 71). The measurements were largely comparable to those of the clinicians, while arc interruption detections were more accurate than those of most clinicians.

CONCLUSION

This study demonstrates that a newly developed automated AI system accurately measures and detects signs of carpal instability on conventional radiographs.

CLINICAL RELEVANCE STATEMENT: This system has the potential to improve detections of carpal arc interruptions and could be a promising tool for supporting clinicians in detecting carpal instability.

Для цитирования: Hendrix Nils, Hendrix Ward, Maresch Bas, van Amersfoort Job, Oosterveld-Bonsma Tineke, Kolderman Stephanie, Vestering Myrthe, Zielinski Stephanie, Rutten Karlijn, Dammeier Jan, Ong Lee-Ling Sharon, van Ginneken Bram, Rutten Matthieu. Artificial intelligence for automated detection and measurements of carpal instability signs on conventional radiographs.. European radiology. 2024. DOI: 10.1007/s00330-024-10744-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.