MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.heliyon.2024.e28652

Медицинская библиотека · Heliyon · 2024

An innovative approach for assessing coronary artery lesions: Fusion of wrist pulse and photoplethysmography using a multi-sensor pulse diagnostic device.

Xiaotian M A, Guo Rui, Zhang Chunke, Yan Jianjun, Zhu Guangyao, Wu Wenjie, Yan Haixia, Hong Leixin

СтатьяПеревод в очереди

Аннотация

Coronary heart disease (CHD) is a leading cause of mortality globally and poses a significant threat to public health. Coronary angiography (CAG) is a gold standard for the clinical diagnosis of CHD, but its invasiveness restricts its widespread application. In this study, we utilized a pulse diagnostic device equipped with pressure and photoelectric sensors to synchronously and non-invasively capture wrist pressure pulse waves and fingertip photoplethysmography (FPPG) of patients undergoing CAG. The extracted features were utilized in constructing random forest-based models to assessing the severity of coronary artery lesions. Notably, Model 3, incorporating both wrist pulse and FPPG features, surpassed Model 1 (solely utilizing wrist pulse features) and Model 2 (solely utilizing FPPG features). Model3 achieved an Accuracy, Precision, Recall, and F1-score of 78.79%, 78.69%, 78.79%, and 78.70%, respectively. Compared to Model1 and Model2, Model 3 exhibited improvements by 4.55%, 5.25%, 4.55%, and 5.12%, and 6.06%, 6.58%, 6.06%, and 6.54% respectively. This fusion of wrist pulse and FPPG features in Model 3 highlights the advantages of multi-source information fusion for model optimization. Additionally, this research provides invaluable insights into the novel development of diagnostic devices imbued with TCM principles and their potential in managing cardiovascular diseases.

Для цитирования: Xiaotian M A, Guo Rui, Zhang Chunke, Yan Jianjun, Zhu Guangyao, Wu Wenjie, Yan Haixia, Hong Leixin. An innovative approach for assessing coronary artery lesions: Fusion of wrist pulse and photoplethysmography using a multi-sensor pulse diagnostic device.. Heliyon. 2024. DOI: 10.1016/j.heliyon.2024.e28652.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.