MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5606/tftrd.2020.5781

Медицинская библиотека · Turkish journal of physical medicine and rehabilitation · 2020

The reliability and validity of The Turkish version of Multidimensional Fatigue Inventory-20 for the evaluation of different dimensions of fatigue in patients with fibromyalgia.

Başoğlu Fatma, Öncü Julide, Kuran Banu, Alptekin Hasan Kerem

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

In this study, we aimed to evaluate the validity and reliability of the Multidimensional Fatigue Inventory-20 (MFI-20) for Turkish patients with fibromyalgia (FM).

PATIENTS AND

METHODS

Between February 2011 and September 2011, a total of 120 female patients (mean age 45±9.1 years; range, 20 to 60 years) admitted to our outpatient clinic with extensive pain and fatigue and diagnosed with FM according to 1990 and 2010 American College of Rheumatology criteria were included in this study. The MFI-20 was translated according to forward-backward translation procedure. For the test-retest reliability, the patients re-filled out the scale 48 hours after the first application. Structural validity was evaluated with confirmatory factor analysis (CFA). Reliability was assessed by internal consistency with Cronbach alpha and test-retest reliability was assessed by intra-class correlation coefficient (ICC). For convergent validity, Spearman rho correlation coefficient was used for relevance analysis with the Fatigue Impact Scale (FIS), visual analog scale (VAS)-pain, VAS-fatigue, and Short Form-36 (SF-36) questionnaires.

RESULTS

The total Cronbach alpha coefficient was found to be 0.92 (range, 0.78 to 0.93). The CFA showed good structural validity and revealed five dimensions. The ICC coefficient was found to be 0.934. All correlation coefficients between the MFI and FIS were calculated as above 0.80, indicating a strong relationship.

CONCLUSION

The results of this study show that the Turkish version of the MFI-20 has a high internal consistency and reasonable construct validity. It is a valid and reliable measurement of the assessment of fatigue in patients with FM multidimensionality.

Для цитирования: Başoğlu Fatma, Öncü Julide, Kuran Banu, Alptekin Hasan Kerem. The reliability and validity of The Turkish version of Multidimensional Fatigue Inventory-20 for the evaluation of different dimensions of fatigue in patients with fibromyalgia.. Turkish journal of physical medicine and rehabilitation. 2020. DOI: 10.5606/tftrd.2020.5781.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.