MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmbbm.2015.12.022

Медицинская библиотека · Journal of the mechanical behavior of biomedical materials · 2015

Comparison of 10-year clinical wear of annealed and remelted highly cross-linked polyethylene: A propensity-matched cohort study.

Hamai Satoshi, Nakashima Yasuharu, Mashima Naohiko, Yamamoto Takuaki, Kamada Tomomi, Motomura Goro, Imai Hiroshi, Fukushi Jun-Ichi, Miura Hiromasa, Iwamoto Yukihide

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

No previous studies comparing the clinical wear rates of the two different kinds of cross-linked ultra-high-molecular-weight polyethylene (XLPE), annealed and remelted, are available. We compared the creep and steady wear rates of 36 matched pairs (72 hips in total) adjusting for baseline characteristics with propensity score matching techniques. Zirconia femoral heads with 26-mm diameter were used in all cases. The femoral-head cup penetration was measured digitally on radiographs. Significantly greater creep (p=0.006) was detected in the remelted (0.234mm) than annealed (0.159mm) XLPE. However, no significant difference (p=0.19) was found between the steady wear rates (0.003 and 0.008mm/year, respectively) of the annealed and remelted XLPE. Multiple regression analyses showed that remelted XLPE is significant independent variable (p<0.001) that is positively associated with creep. However, the patient age and body weight, cup size, the liner thickness, cup inclination, follow-up periods, and postoperative Merle d'Aubigné hip score had no significant effects (p>0.05) on the steady wear rates. No patients exhibited above the osteolysis threshold of 0.1mm/year, progressive radiolucencies, osteolysis, or polyethylene fracture. This propensity-matched cohort study document no significant difference in wear resistant performances of annealed and remelted XLPE over an average period of 10 years.

Для цитирования: Hamai Satoshi, Nakashima Yasuharu, Mashima Naohiko, Yamamoto Takuaki, Kamada Tomomi, Motomura Goro, Imai Hiroshi, Fukushi Jun-Ichi, Miura Hiromasa, Iwamoto Yukihide. Comparison of 10-year clinical wear of annealed and remelted highly cross-linked polyethylene: A propensity-matched cohort study.. Journal of the mechanical behavior of biomedical materials. 2015. DOI: 10.1016/j.jmbbm.2015.12.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.