MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/clr.14207

Медицинская библиотека · Clinical oral implants research · 2023

The influence of titanium-base abutment geometry and height on mechanical stability of implant-supported single crowns.

Karasan Duygu, Pitta João, Zarauz Cristina, Strasding Malin, Liu Xinran, Fehmer Vincent, Sailer Irena

СтатьяПеревод в очереди

Аннотация

AIM: This study aimed to investigate the influence of titanium base (ti-base) abutment macro- and micro-geometry on the mechanical stability of polymer-infiltrated ceramic network (PICN) screw-retained implant-supported single crowns (iSCs).

MATERIALS AND

METHODS

Twelve specimens per group were used, comprising six different implant/ti-base abutment combinations restored with PICN iSCs: Nb-T (gingival height [GH]: 1.5 mm, prosthetic height [PH]: 4.3 mm), CC (GH: 0.8 mm, PH: 4.3 mm), CC-P (GH: 0.8 mm, PH: 7 mm), Nb-V (GH: 1.5 mm, PH: 6 mm), St (GH: 1.5 mm, PH: 5.5 mm), and Th (GH: 0.5 mm, PH: 9 mm). The specimens underwent thermo-mechanical aging, and those that survived were subsequently subjected to static loading until failure. The data were analyzed using a one-way ANOVA test followed by Tukey post hoc test (α = .05).

RESULTS

All specimens survived thermo-mechanical aging without complications, namely, visible cracks, debonding, or screw loosening. Th group demonstrated the highest strength values among all the groups, with significant differences compared to Nb-T (p < .05), CC (p < .001), and St (p < .001). Additionally, CC-P group exhibited significantly superior fracture strength results compared to CC (p < .05) and St (p < .05).

CONCLUSION

The choice of ti-base, particularly prosthetic height, had a significant influence on fracture resistance of PICN iSCs. Nevertheless, the height or geometrical features of the ti-base did not exhibit a significant influence on the mechanical behavior of the iSC/ti-base assembly under thermomechanical loading, as all specimens withstood the aging without complication or failure.

Для цитирования: Karasan Duygu, Pitta João, Zarauz Cristina, Strasding Malin, Liu Xinran, Fehmer Vincent, Sailer Irena. The influence of titanium-base abutment geometry and height on mechanical stability of implant-supported single crowns.. Clinical oral implants research. 2023. DOI: 10.1111/clr.14207.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.