BACKGROUND

Xpert MTB/RIF Ultra (Ultra) aimed to improve the specificity in identifying rifampicin-resistant tuberculosis (RR-TB), compared to Xpert MTB/RIF.

METHODS

In a nationwide study in Rwanda, patients diagnosed with RR-TB by Ultra between December 2021 and January 2024 underwent repeat Ultra testing, complemented by rpoB gene sequencing and phenotypic drug-susceptibility testing (pDST), serving as reference tests.

RESULTS

Of 129 patients initially diagnosed with RR-TB by Ultra, only 41 (32%) had concordant rifampicin results upon repeat Ultra testing. The remaining 88 patients (68%) had unconfirmed resistance on repeat Ultra. Reference testing was available for 40 (98%) of 41 confirmed cases, all verified as true RR-TB. Among 88 unconfirmed cases, reference testing was available for 61 (69%), with 7 (11%) confirmed as true RR-TB, whereas 54 (89%) were found to have rifampicin-susceptible TB. Notably, 89% of 55 patients with very low bacillary loads on their initial Ultra had false RR-TB results, a significantly higher risk of false resistance compared to other bacillary load categories combined (risk ratio: 8.20; 95% confidence interval [CI]: 3.56-18.85; P < .001). Consequently, 53% (54/101) of initial RR patients with available reference testing received unnecessary RR-TB treatment.

CONCLUSIONS

Ultra represents a valuable tool for rapid RR-TB detection; however, in low prevalence settings its low positive predictive value for RR detection is largely driven by samples with very low bacillary loads. As programs expand active case-finding and early detection of asymptomatic disease, the proportion of TB detected with very low bacillary load will increase. Diagnostic algorithms require adjustments to prevent unnecessary RR-TB treatment.

Для цитирования: Cuella-Martin Isabel, Hakizayezu Francois, Ahmed Aymen, Runyambo Docteur, Niyompano Hosee, Keysers Jelle, De Rijk Willem Bram, Mulders Wim, Mitchell Ellen M H, Decroo Tom, Habimana Yves Mucyo, Migambi Patrick, Muvunyi Claude Mambo, de Jong Bouke C, Rigouts Leen, Ngabonziza Jean Claude Semuto. Paucibacillary Tuberculosis Drives the Low Positive Predictive Value of Xpert MTB/RIF Ultra for Rifampicin Resistance Detection in Low-Prevalence Settings.. Clinical infectious diseases : an official publication of the Infectious Diseases Society of America. 2025. DOI: 10.1093/cid/ciaf132.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.