MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5301/hipint.5000302

Медицинская библиотека · Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2016

Use of an anatomic long-stemmed component in femoral impaction grafting.

Westerman Richard W, Timperley Andrew J

Клинический случайСтатьяПеревод в очереди

Аннотация

We describe a challenging femoral revision for aseptic loosening in a relatively young and active man. The femur had gross osteolysis, an absent calcar and a cortical diaphyseal defect at the level of the isthmus (Paprosky 3b defect). The cortical defects were repaired and the whole femur then restored with Femoral Impaction Grafting (FIG) using custom-made impaction instruments and an anatomic shaped collarless, polished, tapered femoral component.In the active adult, bone restoring revision techniques such as impaction grafting should be considered to give a realistic prospect of host bone augmentation rather than simply aiming for a distally fixed stem in a patulous femoral canal.

Для цитирования: Westerman Richard W, Timperley Andrew J. Use of an anatomic long-stemmed component in femoral impaction grafting.. Hip international : the journal of clinical and experimental research on hip pathology and therapy. 2016. DOI: 10.5301/hipint.5000302.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.