BACKGROUND

Lateral malleolus fractures occur frequently. The common techniques for fixing purely lateral malleolus fractures are often challenging, owing to the extent of soft tissue damage and fracture non-union. Herein, we report a new treatment that entails minimally invasive insertion and continuous compression of the broken ends as a novel technique, and evaluate its clinical results.

METHODS

This study enrolled 21 patients (13 males and 8 females; mean age 32.06±3.45 years, range 23-69 years) with purely lateral malleolus fractures. Each patient underwent open reduction treatment with a mini locking plate for internal fixation and compression of the fracture end with an Arched Shape-Memory Connector (ASC). The clinical assessments were made using the American Orthopedic Foot and Ankle Society (AOFAS) scores, which were recorded at the final follow-up visit.

RESULTS

The patients were followed for an average of 14.7±1.2 months (range, 12-18 months). None of the patients showed surgical failure, and all of the purely lateral malleolus fractures healed in an average of 12.6±1.5 weeks (range, 10-16 weeks). The mean AOFAS score was 88.94 (range, 83-90).

CONCLUSIONS

The new treatment had beneficial outcomes for purely lateral malleolus fractures. Mini locking plates are minimally invasive for surgical intervention, and combined with continuous concentrated compression with an ASC to accelerate osseous healing, they aid in restoration of function and enable early rehabilitation with a low incidence of postoperative complications.

Для цитирования: Xia Demeng, Zhang Yuntong, Ou Tianle, Wang Yang, Hao Zichen, Zhou Panyu, Xu Shuogui. Combination of mini locking plate and nitinol arched shape-memory connector for purely lateral malleolus fractures: technique and clinical results.. Annals of translational medicine. 2020. DOI: 10.21037/atm-20-4055.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.