DOI 10.1136/bjo-2023-324528

Медицинская библиотека · The British journal of ophthalmology · 2024

Detection of glaucoma progression on longitudinal series of en-face macular optical coherence tomography angiography images with a deep learning model.

Mohammadzadeh Vahid, Liang Youwei, Moghimi Sasan, Xie Pengtao, Nishida Takashi, Mahmoudinezhad Golnoush, Eslani Medi, Walker Evan, Kamalipour Alireza, Micheletti Eleonora, Wu Jo-Hsuan, Christopher Mark, Zangwill Linda M, Javidi Tara, Weinreb Robert N

СтатьяНаблюдательное исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND/AIMS: To design a deep learning (DL) model for the detection of glaucoma progression with a longitudinal series of macular optical coherence tomography angiography (OCTA) images.

METHODS

202 eyes of 134 patients with open-angle glaucoma with ≥4 OCTA visits were followed for an average of 3.5 years. Glaucoma progression was defined as having a statistically significant negative 24-2 visual field (VF) mean deviation (MD) rate. The baseline and final macular OCTA images were aligned according to centre of fovea avascular zone automatically, by checking the highest value of correlation between the two images. A customised convolutional neural network (CNN) was designed for classification. A comparison of the CNN to logistic regression model for whole image vessel density (wiVD) loss on detection of glaucoma progression was performed. The performance of the model was defined based on the confusion matrix of the validation dataset and the area under receiver operating characteristics (AUC).

RESULTS

The average (95% CI) baseline VF MD was -3.4 (-4.1 to -2.7) dB. 28 (14%) eyes demonstrated glaucoma progression. The AUC (95% CI) of the DL model for the detection of glaucoma progression was 0.81 (0.59 to 0.93). The sensitivity, specificity and accuracy (95% CI) of DL model were 67% (34% to 78%), 83% (42% to 97%) and 80% (52% to 95%), respectively. The AUC (95% CI) for the detection of glaucoma progression based on the logistic regression model was lower than the DL model (0.69 (0.50 to 0.88)).

CONCLUSION

The optimised DL model detected glaucoma progression based on longitudinal macular OCTA images showed good performance. With external validation, it could enhance detection of glaucoma progression.

TRIAL REGISTRATION NUMBER: NCT00221897.

Для цитирования: Mohammadzadeh Vahid, Liang Youwei, Moghimi Sasan, Xie Pengtao, Nishida Takashi, Mahmoudinezhad Golnoush, Eslani Medi, Walker Evan, Kamalipour Alireza, Micheletti Eleonora, Wu Jo-Hsuan, Christopher Mark, Zangwill Linda M, Javidi Tara, Weinreb Robert N. Detection of glaucoma progression on longitudinal series of en-face macular optical coherence tomography angiography images with a deep learning model.. The British journal of ophthalmology. 2024. DOI: 10.1136/bjo-2023-324528.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.