BACKGROUND

The use of cephalo-medullary nails (CMN) is a widely accepted management option for the treatment of unstable per-trochanteric hip fractures. A growing body of literature has reported good functional and radiological outcomes in patients managed with a dynamic hip screw supplemented with a trochanteric stabilisation plate (DHS w/ TSP). However, a robust meta-analysis does not exist in the current literature comparing the two fixation methods.

PURPOSES: Management of these kinds of injuries is very challenging in orthopaedic practice, yet no strong evidence is in place to delineate which implant gives the best results. This meta-analysis is the first to determine the efficacy of CMN versus DHS w/ TSP.

METHODS

An up-to-date literature search was performed using a predetermined search strategy and eligibility criteria. All suitable literature was appraised for methodological quality using the Cochrane's collaboration tool. Hospital stay, operative time, intra-operative complication rate, mechanical failure rate, infection rates, revision rates and functional outcomes were all considered.

RESULTS

A total of five studies were included in the meta-analysis. The results of this analysis suggest that CMN is only associated with lower revision rates when compared to DHS w/ TSP; however, no significant difference was found in terms of hospital stay, operative time, blood transfusion, complications rate and functional outcome.

CONCLUSION

Both CMN and DHS w/TSP proved to be reliable in the management of unstable per-trochanteric fractures; however, more extensive datasets are required to draw robust conclusions.

Для цитирования: Selim Amr, Ponugoti Nikhil, Naqvi Ali Zain, Magill Henry. Cephalo-medullary nailing versus dynamic hip screw with trochanteric stabilisation plate for the treatment of unstable per-trochanteric hip fractures: a meta-analysis.. Journal of orthopaedic surgery and research. 2021. DOI: 10.1186/s13018-020-02193-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.