MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00256-024-04662-y

Медицинская библиотека · Skeletal radiology · 2024

Diagnostic efficacy of high-frequency Grey-scale ultrasonography and Sono-elastography in grading the severity of carpal tunnel syndrome in comparison to nerve conduction studies.

Prakash Arjun, Vinutha H, Janardhan D C, Mouna R Mohit, Sushmitha P S, Sajjan Shantkumar, Samanvitha H

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To correlate the cross-sectional area (CSA) and elasticity of the median nerve (MN) measured at carpal tunnel inlet between healthy controls and various degrees of carpal tunnel syndrome (CTS) graded as per nerve conduction studies (NCS).

MATERIALS AND

METHODS

A total of 53 patients (with 81 wrists) presenting with clinical symptoms characteristic of CTS, having their diagnosis confirmed and severity graded by NCS, and 48 healthy controls (with 96 wrists) were included in the study. All the study participants underwent wrist ultrasound which included initial Grey-scale USG followed by strain and shear wave elastography. The CSA and elasticity (in terms of strain ratio and shear modulus) of MN were measured at the carpal tunnel inlet. Statistical analysis was performed using the Mann-Whitney U test to compare between the two groups and for subgroup analysis of cases. The diagnostic performance of each variable was evaluated using the receiver operating characteristic curves.

RESULTS

The mean CSA was 9.20 ± 1.64, 11.48 ± 1.05, 14.83 ± 1.19 and 19.87 ± 2.68 mm2, the mean shear modulus was 17.93 ± 2.81, 23.59 ± 2.63, 32.99 ± 4.14 and 54.26 ± 9.24 kPa and the mean strain ratio was 5.26 ± 0.68, 5.56 ± 0.70, 7.03 ± 0.47 and 8.81 ± 0.94 in control, mild, moderate and severe grades of CTS, respectively (p < 0.001).

CONCLUSION

The combined utility of Grey-scale USG and Elastography may serve as a painless and cost-effective alternative to NCS in grading the severity of CTS.

Для цитирования: Prakash Arjun, Vinutha H, Janardhan D C, Mouna R Mohit, Sushmitha P S, Sajjan Shantkumar, Samanvitha H. Diagnostic efficacy of high-frequency Grey-scale ultrasonography and Sono-elastography in grading the severity of carpal tunnel syndrome in comparison to nerve conduction studies.. Skeletal radiology. 2024. DOI: 10.1007/s00256-024-04662-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.