DOI 10.1016/s1010-7940(02)00411-6
Prospective evaluation of a new sternal closure method with thermoreactive clips.
Аннотация
OBJECTIVES
The role of the sternal closure techniques on the incidence of sternal dehiscence and wound infection are well defined among a high number of other variables involved. In the various series, the incidence of wound complication in cardiac surgery varies from 2 to 8%. The aim of our study is to evaluate the role of thermal-dependent shape-memory Nitillium clips in reducing the incidence of sternal dehiscence following sternotomy.
METHODS
We perspectively randomized 1000 consecutive patients requiring cardiac surgery to evaluate the incidence of sternal wound complications (SWC), sternal dehiscence and/or other related complications. We compared Group I (500 patients), in which sternal closure was achieved with standard sternal wires, with Group II (500 patients), in which sternal approximation was carried out by means of thermoreactive Nitillium clips. The two randomized groups were comparable in terms of age, gender, Euroscore and risk factors for sternal/wound complications.
RESULTS
In our study the overall incidence of SWC was 4.7%. The incidence of SWC was considerably higher in Group I (6.8%) when compared to Group II (2.6%) (P=0.003). Mechanical sternal dehiscence without infection occurred in 14 patients in Group I and in one patient in Group II (P=0.002). Despite sternotomy wound infection occurred similarly in both groups (15 patients in Group I vs. 12 patients in Group II), sternal revision was performed only in patients of Group I (Group I: 9/15 vs. Group II: 0/12; P=0.001).
CONCLUSION
Thermal shape-memory Nitillium clips provided superior results in sternal osteosynthesis following midline sternotomy, due to a considerable reduction of sternal dehiscence and related complications. The clinical benefit of Nitillium clips was demonstrated even in patients with several risk factors for SWC.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.