Comparison of Low-Dose Computed Tomography Versus Conventional-Dose Computed Tomography in the Evaluation of Distal Radius Fractures.

Zeng Steven L, Grier A Jordan, Langdell Hannah C, Blevins Kier M, Tian William M, French Robert J, Mithani Suhail K, Hammert Warren C, Klifto Christopher S

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Distal radius fractures (DRFs) are common upper extremity fractures and often require surgical fixation when they are intraarticular. Preoperative computed tomography (CT) has emerged as a surgical planning tool to evaluate intraarticular DRFs. Although CT affords additional details, patients receive higher radiation doses than standard radiographs. We aim to develop a low-dose CT (LDCT) protocol, relative to the institutional standard-dose CT wrist for intraarticular DRFs although providing adequate detail for surgical decision-making.

METHODS

A single-institution prospective study was conducted on patients with intraarticular DRFs who underwent closed reduction and below-elbow splinting who otherwise would undergo wrist CT. Observations were defined as total measurements taken, with each view undergoing 44 measurements. Patients underwent 2 scans with a standard dose and a 10× dose reduction. Articular step and gap measurements were recorded in the sagittal and coronal images.

RESULTS

A total of 11 patients were enrolled (7 women and 4 men). The mean age was 55 years (SD = 20.1). There were a total of 4 reviewers: 1 attending surgeon, 2 resident physicians, and 1 student. When comparing LDCT and conventional-dose CT (CDCT), there were no significant differences in step and gap measurements across all reviewers.

CONCLUSION

This study demonstrated that LDCT provides comparable imaging quality for surgical planning as a CDCT without significant diagnostic decay in the setting of DRFs. This comes with the added benefit of a 10-fold reduction in radiation exposure. These results suggest that LDCT is an opportunity to reduce effective radiation in patients although providing beneficial preoperative imaging.

Для цитирования: Zeng Steven L, Grier A Jordan, Langdell Hannah C, Blevins Kier M, Tian William M, French Robert J, Mithani Suhail K, Hammert Warren C, Klifto Christopher S. Comparison of Low-Dose Computed Tomography Versus Conventional-Dose Computed Tomography in the Evaluation of Distal Radius Fractures.. Hand (New York, N.Y.). 2024. DOI: 10.1177/15589447241232016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.