MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/advs.202308336

Медицинская библиотека · Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024

Multispectral Optoacoustic Tomography Enables In Vivo Anatomical and Functional Assessment of Human Tendons.

Ivankovic Ivana, Lin Hsiao-Chun Amy, Özbek Ali, Orive Ana, Deán-Ben Xosé Luís, Razansky Daniel

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Tendon injuries resulting from accidents and aging are increasing globally. However, key tendon functional parameters such as microvascularity and oxygen perfusion remain inaccessible via the currently available clinical diagnostic tools, resulting in disagreements on optimal treatment options. Here, a new noninvasive method for anatomical and functional characterization of human tendons based on multispectral optoacoustic tomography (MSOT) is reported. Healthy subjects are investigated using a hand-held scanner delivering real-time volumetric images. Tendons in the wrist, ankle, and lower leg are imaged in the near-infrared optical spectrum to utilize endogenous contrast from Type I collagen. Morphology of the flexor carpi ulnaris, carpi radialis, palmaris longus, and Achilles tendons are reconstructed in full. The functional roles of the flexor digitorium longus, hallicus longus, and the tibialis posterior tendons have been visualized by dynamic tracking during toe extension-flexion motion. Furthermore, major vessels and microvasculature near the Achilles tendon are localized, and the global increase in oxygen saturation in response to targeted exercise is confirmed by perfusion studies. MSOT is shown to be a versatile tool capable of anatomical and functional tendon assessments. Future studies including abnormal subjects can validate the method as a viable noninvasive clinical tool for tendinopathy management and healing monitoring.

Для цитирования: Ivankovic Ivana, Lin Hsiao-Chun Amy, Özbek Ali, Orive Ana, Deán-Ben Xosé Luís, Razansky Daniel. Multispectral Optoacoustic Tomography Enables In Vivo Anatomical and Functional Assessment of Human Tendons.. Advanced science (Weinheim, Baden-Wurttemberg, Germany). 2024. DOI: 10.1002/advs.202308336.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.