MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.injury.2020.11.053

Медицинская библиотека · Injury · 2020

Periosteal and endosteal microcirculatory injury following excessive osteosynthesis.

Greksa Ferenc, Butt Edina, Csonka Endre, Jávor Péter, Tuboly Eszter, Török László, Szabo Andrea, Varga Endre, Hartmann Petra

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

We examined the endosteal and periosteal circulations in a patient with fracture non-union who had undergone excessive osteosynthesis applications (two long plates had been placed medially and laterally on the left tibia extending from the proximal 2/7 to the distal 6/7 parts of the bone, while a tibial component of a total knee prosthesis with a long stem had been inserted at the same time).

METHODS

Concomitant perfusion changes were determined in the anterolateral and anteromedial periosteal sheath of the non-united bone ends and intramedullary nearest the osteosynthesis materials during their surgical removal on re-operation. The blood flow in the periosteum and endosteum was recorded by a laser-Doppler flowmetric device using a novel approach. Control measurements were made at identical points of the right tibia.

RESULTS

Considerably lower blood flow values were measured along the tibial periosteal region of the re-operated limb than on the contralateral side (the average perfusion unit (PU) was 76 vs. 106 PU, respectively). Perfusion values were markedly lower in the endosteal region (average values of approx. 30 PU) in the control tibia and were even more diminished in the re-operated tibial endosteum (average 9 PU).

CONCLUSIONS

Our study was conducted to characterize the microcirculatory changes of a long bone in response to intramedullary implantation and to provide quantitative data on the insufficiency of local perfusion in a patient with fracture non-union. Our results highlight the association between local perfusion failure and the unfavorable outcome (i.e. fracture non-union), confirming that the vital aspects of the microcirculation should not be disregarded when aiming for mechanical stability. Microcirculatory measurements constitute a new area of improvement in planning the adequate treatment for fracture non-unions with an unclear aetiology. Further refinement of the laser-Doppler technique could have potential benefits for bone surgery and postoperative trauma care in the future.

Для цитирования: Greksa Ferenc, Butt Edina, Csonka Endre, Jávor Péter, Tuboly Eszter, Török László, Szabo Andrea, Varga Endre, Hartmann Petra. Periosteal and endosteal microcirculatory injury following excessive osteosynthesis.. Injury. 2020. DOI: 10.1016/j.injury.2020.11.053.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.