MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jum.14964

Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2019

Diagnostic Accuracy of Echo Envelope Statistical Modeling Compared to B-Mode and Power Doppler Ultrasound Imaging in Patients With Clinically Diagnosed Lateral Epicondylosis of the Elbow.

Bureau Nathalie J, Destrempes François, Acid Souad, Lungu Eugen, Moser Thomas, Michaud Johan, Cloutier Guy

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

To compare the accuracy of homodyned K quantitative ultrasound (QUS) with that of B-mode and Doppler ultrasound imaging for discriminating between lateral epicondylosis (LE) and asymptomatic elbows.

METHODS

This prospective study received Institutional Review Board approval, and participants provided written informed consent. Between February 2015 and March 2017, 30 LE elbows in 27 patients and 24 asymptomatic elbows in 13 volunteers underwent B-mode, Doppler, and radiofrequency ultrasound imaging of the common extensor tendon (CET) and radial collateral ligament (RCL). Two readers classified the elbows independently on the basis of a review of B-mode and Doppler images. The global and local estimates of QUS parameters (μ n , 1/α, and k) were computed in the CET and CET-RCL regions, respectively, and the area of each region was calculated. A random-forest classifier identified the most discriminating 3-parameter combination: CET global estimate of 1/α, CET-RCL area, and local estimate of k.

RESULTS

The patients with LE had a mean age of 50 years (range, 31-66 years), and the volunteers had a mean age of 50 years (range, 37-57 years). The area under the receiver operating characteristic curve, sensitivity, and specificity of reader 1, reader 2, and the QUS-based model were 0.80 (95% confidence interval [CI], 0.66-0.95), 0.72 (95% CI, 0.56-0.89), and 0.88 (95% CI, 0.72-1.04); 0.79 (95% CI, 0.66-0.93), 0.65 (95% CI, 0.47-0.82), and 0.84 (95% CI, 0.67-1.01); and 0.82 (95% CI, 0.80-0.85), 0.73, and 0.79, respectively.

CONCLUSIONS

An automated, computer-based QUS technique diagnosed LE with accuracy of 0.82. This technique could provide quantitative biomarkers for the characterization of LE disease.

Для цитирования: Bureau Nathalie J, Destrempes François, Acid Souad, Lungu Eugen, Moser Thomas, Michaud Johan, Cloutier Guy. Diagnostic Accuracy of Echo Envelope Statistical Modeling Compared to B-Mode and Power Doppler Ultrasound Imaging in Patients With Clinically Diagnosed Lateral Epicondylosis of the Elbow.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2019. DOI: 10.1002/jum.14964.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.