MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/dj11090207

Медицинская библиотека · Dentistry journal · 2023

Reliability and Failure Mode of Ti-Base Abutments Supported by Narrow/Wide Implant Systems.

Benalcázar-Jalkh Ernesto B, de Carvalho Laura F, Alves Larissa M M, Campos Tiago M B, Sousa Edisa de Oliveira, Bergamo Edmara T P, Coelho Paulo G, Gierthmuehlen Petra C, Spitznagel Frank A, Zahoui Abbas, Bonfante Estevam A

СтатьяПеревод в очереди

Аннотация

To assess the reliability and failure modes of Ti-base abutments supported by narrow and wide-diameter implant systems. Narrow (Ø3.5 × 10 mm) and wide (Ø5 × 10 mm) implant systems of two different manufacturers with internal conical connections (16°) and their respective Ti-base abutments (3.5 and 4.5 mm) were evaluated. Ti-base abutments were torqued to the implants, standardized metallic maxillary incisor crowns were cemented, and step stress accelerated life testing of eighteen assemblies per group was performed in three loading profiles: mild, moderate, and aggressive until fracture or suspension. Reliability for missions of 100,000 cycles at 100 and 150 N was calculated, and fractographic analysis was performed. For missions at 100 N for 100,000 cycles, both narrow and wide implant systems exhibited a high probability of survival (≥99%, CI: 94-100%) without significant differences. At 150 N, wide-diameter implants presented higher reliability (≥99%, CI: 99-100%) compared to narrow implants (86%, CI: 61-95%), with no significant differences among manufacturers. Failure mode predominantly involved Ti-base abutment fractures at the abutment platform. Ti-base abutments supported by narrow and wide implant systems presented high reliability for physiologic masticatory forces, whereas for high load-bearing applications, wide-diameter implants presented increased reliability. Failures were confined to abutment fractures.

Для цитирования: Benalcázar-Jalkh Ernesto B, de Carvalho Laura F, Alves Larissa M M, Campos Tiago M B, Sousa Edisa de Oliveira, Bergamo Edmara T P, Coelho Paulo G, Gierthmuehlen Petra C, Spitznagel Frank A, Zahoui Abbas, Bonfante Estevam A. Reliability and Failure Mode of Ti-Base Abutments Supported by Narrow/Wide Implant Systems.. Dentistry journal. 2023. DOI: 10.3390/dj11090207.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.