Autoinflammation Around AES Total Ankle Replacement Implants.

Koivu Helka, Takakubo Yuya, Mackiewicz Zygmunt, Al-Samadi Ahmed, Soininen Antti, Peled Nitai, Kukis Modestas, Trokovic Nina, Konttinen Yrjö T

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Failure of total ankle replacement (TAR) can be characterized by early peri-implant osteolysis even in the presence of very modest numbers of wear particles. The hypothesis of the study was that this reaction is in part mediated by autoinflammatory responses mediated via damage-associated molecular patterns (DAMPs, danger signals) and pattern-recognizing danger signal receptors (PRRs).

METHODS

Peri-implant tissue and control samples from 10 patients with AES implants were immunostained for hypoxia inducible factor-1α (HIF-1α), activated caspase-3, high-mobility group box 1 (HMGB1), receptor for advanced glycation end product (RAGE), and toll-like receptors TLR2 and TLR4. Results were evaluated on a 0 to 4 scale (from 0% to >50% stained area).

RESULTS

Peri-implant tissue around failed TAR implants had a relatively high mean HIF-1α score of 3 on a scale, which however was similar in control samples. HMGB1 (a DAMP) was seen to be mobilized from nuclei to cellular cytoplasm, and the active caspase-3(+) cells were increased. All PRRs were increased in revision samples.

CONCLUSIONS

Increased expression of HMGB1 and other danger signals together with increased PRR-dependent responsiveness could contribute to autoinflammatory peri-implantitis, multilocular cyst formation, and osteolysis in failed TAR implants.

LEVEL OF EVIDENCE: Level IV, case series.

Для цитирования: Koivu Helka, Takakubo Yuya, Mackiewicz Zygmunt, Al-Samadi Ahmed, Soininen Antti, Peled Nitai, Kukis Modestas, Trokovic Nina, Konttinen Yrjö T. Autoinflammation Around AES Total Ankle Replacement Implants.. Foot & ankle international. 2015. DOI: 10.1177/1071100715596608.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.