MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-022-07341-5

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2022

Serum metal ion levels following spinal deformity surgery: a case-control study of 182 individuals.

Fell Daniel, Diarbakerli Elias, Gerdhem Paul

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: The aim of this study is to evaluate the levels of chromium (Cr), cobalt (Co), and titanium (Ti) after instrumented fusion for scoliosis.

METHODS

Serum samples were collected at median 2.24 (range 0.1-38.8) years after fusion surgery for scoliosis in 91 individuals, of which 71 had been treated with steel implants and 20 with titanium implants. 91 sex and age-matched non-surgically treated individuals with scoliosis were used as controls. Levels of Cr, Co, and Ti were measured.

RESULTS

In the 91 surgically treated individuals median levels of Cr were 0.54 µg/l vs 0 µg/l in the 91 controls, p < 0.001. Corresponding results for Co were 0.29 µg/l vs. 0.24 µg/l, p = 0.19, and for Ti were 0 µg/l vs. 0 µg/l, p < 0.001. In the individuals with steel implants and their corresponding controls median Cr levels were 0.63 µg/l vs. 0.00 µg/l, p < 0.001 and Co levels 0.27 µg/l vs. 0.23 µg/l, p = 0.36. No Ti was detected. In the individuals with titanium implants, median Cr levels were 0 µg/l vs. 0 µg/l in their corresponding controls, p = 0.38. Corresponding results for Co was 0.39 µg/l vs. 0.31 µg/l, p = 0.27 and for Ti 4.31 µg/l vs. 0 µg/l, p < 0.001. In the individuals with steel implants a negative correlation between implant time in situ and levels of Cr was found ([Formula: see text] = - 0.52, p < 0.001) but not with Co ([Formula: see text] = - 0.14, p = 0.23). Ti was not detected. In the individuals with titanium implants, there was no correlation between implant time in situ and levels of Cr ([Formula: see text] = 0.36, p = 0.12), Co ([Formula: see text] = - 0.12, p = 0.60) or Ti ([Formula: see text] = 0.22, p = 0.35).

CONCLUSION

The use of stainless steel and titanium implants in spinal fusion surgery is associated with elevated metal ion concentrations several years after surgery.

Для цитирования: Fell Daniel, Diarbakerli Elias, Gerdhem Paul. Serum metal ion levels following spinal deformity surgery: a case-control study of 182 individuals.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2022. DOI: 10.1007/s00586-022-07341-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.