MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2020.109159

Медицинская библиотека · European journal of radiology · 2020

Improved diagnostic confidence in evaluating bone non-union using virtual monochromatic dual-energy CT.

Donders J C E, Wellenberg R H H, Streekstra G J, Maas M, Kloen P

СтатьяПеревод в очереди

Аннотация

PURPOSE: The aim of this study was to determine whether virtual monochromatic dual-energy CT imaging improves the evaluation of suspected non-union of the appendicular skeleton treated with titanium or stainless steel intramedullary nails and plates.

METHOD: Forty-one patients with a clinical suspected non-union with hardware in place were included and scanned on a dual-source CT-scanner using 100/Sn150kVp. Images including titanium hardware were extracted at 130 keV. Images including stainless steel hardware were extracted at 150 keV. Monochromatic 70 keV images served as reference. Non-union confirmed during revision surgery was used as gold standard. A musculoskeletal radiologist and orthopedic trauma surgeon evaluated images on image quality, degree and location of consolidation, non-union type and diagnostic confidence.

RESULTS

Likert scores with respect to image quality improved from 0.88 to 1.83 (p < 0.001) in high (130 and 150) keV images. High keV images reduced the number of false negative non-unions based on consolidation grade with 5% (p = 0.283). Agreement between observers regarding location of consolidation and non-union type did not improve in 130 and 150 keV images. Diagnostic confidence improved from 1.43 to 2.37 in high keV images compared to 70 keV images (p < 0.001). Overall diagnostic confidence was higher in intramedullary nails than plates (p < 0.05).

CONCLUSIONS

Use of virtual monochromatic 130 and 150 keV dual-energy CT compared to 70 keV images improves the evaluation of suspected non-union of the appendicular skeleton treated with titanium or stainless steel intramedullary nails and plates.

Для цитирования: Donders J C E, Wellenberg R H H, Streekstra G J, Maas M, Kloen P. Improved diagnostic confidence in evaluating bone non-union using virtual monochromatic dual-energy CT.. European journal of radiology. 2020. DOI: 10.1016/j.ejrad.2020.109159.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.