MedElevator Войти в исследования
← Поиск публикаций

DOI 10.12200/j.issn.1003-0034.2023.04.015

Медицинская библиотека · Zhongguo gu shang = China journal of orthopaedics and traumatology · 2023

[Double-column Die-punch fractures of distal radius treated with butterfly plate fixation via Henry approach].

Xia Hai-Bo, Lan Jun, Jiang Li-Qing, Yang Hua-Fei, Niu Xiao-Hui

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To explore clinical effect of open reduction and internal fixation with Henry's approach butterfly plate in treating double-column Die-punch fractures of distal radius.

METHODS

From January 2018 to June 2021, 26 patients with double-column Die-column distal radius were treated with open reduction and internal fixation through Henry's surgical approach and using distal radius volar column plate(butterfly plate), including 14 males and 12 females, aged from 20 to 75 years old with an average age of (44.2±3.4) years old. Postopertaive complications were observed, Gartland-Werley score at 12 months after opertaion was used to evaluate wrist joint function.

RESULTS

All 26 patients were followed up from 10 to 18 months with an average of(13.4±0.8) months. All fractures were obtained fracture union, the time ranged from 8.5 to 15.8 weeks with an average of (11.4±0.5) weeks. All incisions healed at stageⅠwithout infection, nerve injury and internal fixation failure occurred. Postoperative Gartland-Werley score at 12 months was (3.65±0.36), and 16 patients got excellent result, 8 good and 2 moderate.

CONCLUSION

Open reduction and internal fixation with butterfly plate for the treatment of double-column Die-punch fractures of the distal radius through volar Henry approach could obtain satisfactory clinical outcomes.

Для цитирования: Xia Hai-Bo, Lan Jun, Jiang Li-Qing, Yang Hua-Fei, Niu Xiao-Hui. [Double-column Die-punch fractures of distal radius treated with butterfly plate fixation via Henry approach].. Zhongguo gu shang = China journal of orthopaedics and traumatology. 2023. DOI: 10.12200/j.issn.1003-0034.2023.04.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.