MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/01652176.2014.966172

Медицинская библиотека · The veterinary quarterly · 2014

Loop-mediated isothermal amplification (LAMP) test for specific and rapid detection of Brucella abortus in cattle.

Karthik K, Rathore Rajesh, Thomas Prasad, Arun T R, Viswas K N, Agarwal R K, Manjunathachar H V, Dhama Kuldeep

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Brucella abortus, the major causative agent of abortion in cattle and a zoonotic pathogen, needs to be diagnosed at an early stage. Loop-mediated isothermal amplification (LAMP) test is easy to perform and also promising to be adapted at field level.

OBJECTIVE

To develop a LAMP assay for specific and rapid detection of B. abortus from clinical samples of cattle.

METHODS

LAMP primers were designed targeting BruAb2_0168 region using specific software tool and LAMP was optimized. The developed LAMP was tested for its specificity with 3 Brucella spp. and 11 other non-Brucella spp. Sensitivity of the developed LAMP was also carried out with known quantity of DNA. Cattle whole blood samples and aborted fetal stomach contents were collected and used for testing with developed LAMP assay and results were compared with polymerase chain reaction (PCR).

RESULTS

The developed LAMP assay works at 61 °C for 60 min and the detection limit was observed to be 100-fold more than the conventional PCR that is commonly used for diagnosis of B. abortus. Clinical sensitivity and specificity of the developed LAMP assay was 100% when compared with Rose Bengal plate test and standard tube agglutination test. SYB® green dye I was used to visualize the result with naked eye.

CONCLUSION

The novelty of the developed LAMP assay for specifically detecting B. abortus infection in cattle along with its inherent rapidness and high sensitivity can be employed for detecting this economically important pathogen of cattle at field level as well be exploited for screening of human infections.

Для цитирования: Karthik K, Rathore Rajesh, Thomas Prasad, Arun T R, Viswas K N, Agarwal R K, Manjunathachar H V, Dhama Kuldeep. Loop-mediated isothermal amplification (LAMP) test for specific and rapid detection of Brucella abortus in cattle.. The veterinary quarterly. 2014. DOI: 10.1080/01652176.2014.966172.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.