Microcirculation (New York, N.Y. : 1994) · 2018
Automated assessment of absolute nailfold capillary number on videocapillaroscopic images: Proof of principle and validation in systemic sclerosis.
СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Cutolo Maurizio, Trombetta Amelia C, Melsens Karin, Pizzorni Carmen, Sulli Alberto, Ruaro Barbara, Paolino Sabrina, Deschepper Ellen, Smith Vanessa
Аннотация
BACKGROUND: Absolute nailfold capillary number should be a putative biomarker in selected rheumatic diseases but could be time-consuming and not highly repeatable.
OBJECTIVE: To validate an automated software for absolute nailfold capillary number and density evaluation, on NVC images in SSc.
METHODS: An automated software to count nailfold capillary number (AUTOCAPI) had been constructed, through an exploratory image set. Subsequently, application rules have been created to define the ROI in NVC images, through a training images set. The software reliability was assessed through calculation of the ICC between automatic and manual counting, by four independent observers, on the same NVC images.
RESULTS: The following ICC's were obtained per observer, for the patients with SSc (40 images), the healthy (20 images), and the PRP subgroups (20 images), respectively: 0.94, 0.81, and 0.62 (observer 1); 0.94, 0.91, and 0.67 (observer 2); 0.88, 0.56, and 0.64 (observer 3); and 0.88, 0.85, and 0.85 (observer 4).
CONCLUSIONS: The validation of an automated software for measuring absolute nailfold capillary number and density in SSc was achieved. The integration into the pre-existing imaging software should make the assessment of the capillary number in NVC easier, quicker, and standardized.
OBJECTIVE: To validate an automated software for absolute nailfold capillary number and density evaluation, on NVC images in SSc.
METHODS: An automated software to count nailfold capillary number (AUTOCAPI) had been constructed, through an exploratory image set. Subsequently, application rules have been created to define the ROI in NVC images, through a training images set. The software reliability was assessed through calculation of the ICC between automatic and manual counting, by four independent observers, on the same NVC images.
RESULTS: The following ICC's were obtained per observer, for the patients with SSc (40 images), the healthy (20 images), and the PRP subgroups (20 images), respectively: 0.94, 0.81, and 0.62 (observer 1); 0.94, 0.91, and 0.67 (observer 2); 0.88, 0.56, and 0.64 (observer 3); and 0.88, 0.85, and 0.85 (observer 4).
CONCLUSIONS: The validation of an automated software for measuring absolute nailfold capillary number and density in SSc was achieved. The integration into the pre-existing imaging software should make the assessment of the capillary number in NVC easier, quicker, and standardized.