MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2106/00004623-199811000-00013

Медицинская библиотека · The Journal of bone and joint surgery. American volume · 1998

Surface replacement hemiarthroplasty for the treatment of osteonecrosis of the femoral head.

Hungerford M W, Mont M A, Scott R, Fiore C, Hungerford D S, Krackow K A

СтатьяПеревод в очереди

Аннотация

We reviewed the results of thirty-three femoral resurfacing procedures in twenty-five patients who had stage-III or early stage-IV osteonecrosis of the femoral head according to the classification system of Ficat and Arlet. There were no perioperative complications. Thirty hip prostheses (91 percent) survived for a minimum of five years. At a mean of 10.5 years (range, four to fourteen years) postoperatively, sixteen (62 percent) of the twenty-six hips with stage-III disease had a good or excellent Harris hip score. Four of the seven hips with stage-IV disease did not have or need a total hip arthroplasty. Overall, twenty hips (61 percent) had a good or excellent result according to the scoring system of Harris, and thirteen (39 percent) had a fair or poor result and subsequently had or needed a total hip arthroplasty. The mean interval between the hemiarthroplasty and the total hip arthroplasty was sixty months (range, thirty-six to 136 months). These thirteen hips all had a successful clinical result (a Harris hip score of at least 80 points) at a mean of thirty months (range, twenty-four to seventy-two months) after the total hip arthroplasty. The results of the present study suggest that resurfacing of the femoral head can be a successful interim procedure for the management of patients who have Ficat and Arlet stage-III or early stage-IV disease with a large lesion that is not amenable to other treatment options except total hip arthroplasty.

Для цитирования: Hungerford M W, Mont M A, Scott R, Fiore C, Hungerford D S, Krackow K A. Surface replacement hemiarthroplasty for the treatment of osteonecrosis of the femoral head.. The Journal of bone and joint surgery. American volume. 1998. DOI: 10.2106/00004623-199811000-00013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.