MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2020.08.036

Медицинская библиотека · Journal of shoulder and elbow surgery · 2020

A new low-profile anatomic locking plate for fixation of comminuted, displaced greater tuberosity fractures of the proximal humerus.

Zeng Lang-Qing, Chen Yun-Feng, Jiang Yu-Wen, Zeng Lu-Lu, Miao Xiao-Gang, Liang Wei-Guo

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Although various implants exist for the fixation of isolated greater tuberosity fractures, few implants are specifically designed for such fractures. The purpose of this study was to investigate the clinical and radiologic outcomes of open reduction-internal fixation with a low-profile anatomic locking plate for comminuted greater tuberosity fractures of the proximal humerus.

METHODS

From November 2012 to February 2018, 24 patients with displaced and comminuted isolated greater tuberosity fractures were treated with the new low-profile anatomic locking plate. To determine clinical outcomes, we evaluated active range of motion; the visual analog scale pain score; the Constant-Murley score; the Disabilities of the Arm, Shoulder and Hand score; radiographs; and complications.

RESULTS

In all cases, a mean follow-up period of 29.3 months (range, 18-48 months) was completed. All patients achieved bone union with a mean healing time of 11.3 weeks (range, 8-16 weeks). The mean Constant-Murley score was 91.1 points (range, 69-100 points), with a rate of good to excellent results of 95.8%. The average Disabilities of the Arm, Shoulder and Hand score was 9.9 points (range, 2-25 points), and the mean visual analog scale pain score was 1.1 points (range, 0-4 points). Mean active forward flexion, abduction, external rotation, and internal rotation (level) were 157°, 152°, and 40°, and T11, respectively. Postoperatively, 1 patient had persistent shoulder stiffness, and 1 patient had recurrence of shoulder dislocation because of a falling injury during badminton. No serious complications such as subacromial impingement, malunion, nonunion, loss of reduction, or implant failure occurred.

CONCLUSIONS

The new low-profile anatomic locking plate was useful for the treatment of comminuted isolated greater tuberosity fractures as it provided reliable stability and satisfactory radiographic and functional results. The described technique is a simple and effective method and provides a new reliable option for the treatment of isolated greater tuberosity fractures.

Для цитирования: Zeng Lang-Qing, Chen Yun-Feng, Jiang Yu-Wen, Zeng Lu-Lu, Miao Xiao-Gang, Liang Wei-Guo. A new low-profile anatomic locking plate for fixation of comminuted, displaced greater tuberosity fractures of the proximal humerus.. Journal of shoulder and elbow surgery. 2020. DOI: 10.1016/j.jse.2020.08.036.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.